Maintenance and inspection
9
-
53
9
Cable harness in robot
Visual inspection
with multimeter
Check the bushing between the connector on
the stand and the intermediate connectors by
manually moving the wires. Check the protective
coil.
3
.
Exchange
10
Limit switches and dogs (S-,
L- and U-axes)
Using a correspond-
ing tool,
tighten loose screws (replace if necessary).
11
Battery unit in robot
If a battery alarm appears or after the robot has
been operated for 36000 hours, the battery must
be exchanged.
12
S, L, U, R, B and T-axes gear
Grease gun
Check for malfunctions (replace if necessary).
The grease
4
must be refilled every 6000 hours
and exchanged every 12000 hours (see Chapter
9.4.1 "Grease filling the main axes" and 9.4.2
"Grease filling the wrist axes").
Inspection intervals
Item number
1
Schedule (h)
Method
Operation
To be per-
formed by:
Daily
1000
6000
12000
24000
36000
1
2
3