5.11 S: Elevator Parameters
■ S5-12: Stop Distance
Sets the stopping distance when Stop Distance Control is enabled. Refer to
Direct Landing on page 228
and
Leveling
Distance Control on page 229
for details.
No.
Parameter Name
Setting Range
Default
S5-12
Stop Distance
0 to 10000 mm <1>
0 mm
<1> The setting range becomes 0.00 to 393.00 inches w hen the length units are set for inches (o1-12 = 1).
■ S5-13: Direct Landing Minimum Speed Level
Sets the speed level for the start o f Direct Landing. Direct Landing is disabled if the starting speed for Direct Landing is
less than the maximum output speed multiplied by this parameter (E1-04 x S5-13).
No.
Parameter Name
Setting Range
Default
S5-13
Direct Landing M inimum Speed Level
0 to 100%
20%
♦ S6: Faults for Elevator Applications
■ S6-01: Motor Contactor Response Error (SE1) Detection/Reset Selection
Determines when the drive should detect a motor contactor response error (SE1). SE1 is triggered if there is no response
from the motor contactor within the time set in S6-10 after the contactor control output has been set.
No.
Parameter Name
Setting Range
Default
S6-01
Motor Contactor R esponse Error (SE1) D etection/Reset Selection
0 to 2
0
0: Detect during stop, SE1 must be manually reset
1: Detect during stop, SE1 can be autom atically reset
2: No SE1 detection
■ S6-02: Starting Current Error (SE2) Detection Delay Time
Sets a delay time for starting current error (SE2). SE2 is detected when the drive output current is below 25% after the
Up/Down command has been entered and the brake release time and the time set to S6-02 have both passed. The brake
control command will not be issued (brake stays applied).
No.
Parameter Name
Setting Range
Default
S6-02
Starting Current Error (SE2) Detection D elay Time
0.00 to [S1-04 - S1-06]
200 ms
■ S6-04: Output Current Error (SE3) Detection Delay Time
Sets a delay time for detecting an output current fault (SE3). SE3 is detected when the drive output current drops below
25% after the brake has released.
No.
Parameter Name
Setting Range
Default
S6-04
Output Current Error (SE3) Detection Delay Time
0 to 5000 ms
200 ms
■ S6-05: Brake Response Error (SE4) Detection Time
Sets a delay time for detecting a brake response error (SE4). SE4 is detected when an output terminal set for “Brake
release” (И2-ПП = 50) and an input terminal set for “Brake feedback” (И1-ПП = 79) do not match for the time set to
S6-05.
No.
Parameter Name
Setting Range
Default
S6-05
Brake R esponse Error (SE4) Detection Time
0 to 10000 ms
500 ms
230
YASKAWA ELECTRIC SIEP C710616 33D YASKAWA AC Drive L1000A Technical Manual