7
CANopen Lift
Yaskawa CANopen Lift implementation refers to CiA-417: Profile for Lift Control Systems. Supported operation
modes are Profile Velocity mode and Profile Position mode. The Yaskawa CANopen Lift fieldbus option card SI-
L3 is required.
To enable CANopen Lift functionality, set parameter
H5-13 = 5
,
b1-01
and
b1-02 = 6
, and perform a power-
cycle. Some parameters will be changed automatically. Refer to
Added Standard Parameter Dependencies
.
Parameter groups are commonly used in CANopen Lift and in DCP mode. Therefore the following descriptions
refer to DCP parameter and monitor tables.
◆
Characteristics of CANopen Lift Interface
Figure 7.1 Connection Using CANopen Lift
EN