110
YASKAWA
TOEPYAIHV6002A HV600 Drive Programming
1.17
T: Motor Tuning
◆
T0: Tuning Mode Selection
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
T0-00
(1197)
Tuning Mode Selection
Sets the type of Auto-Tuning.
0 : Motor Parameter Tuning
0
(0)
◆
T1: Induction Motor Auto-Tuning
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
T1-00
(0700)
Motor 1/Motor 2
Selection
Sets which motor to tune when motor 1/2 switching is enabled.
You can only use the keypad to set this parameter. You cannot use external input terminals
to set it.
Note:
This parameter is available when
H1-xx = 16 [Motor 2 Selection]
. The keypad will not
show this parameter when
H1-xx ≠ 16
.
1 : Motor 1 (sets E1-xx, E2-xx)
2 : Motor 2 (sets E3-xx, E4-xx)
1
(1, 2)
T1-01
(0701)
Auto-Tuning Mode
Selection
Sets the type of Auto-Tuning.
0 : Rotational Auto-Tuning
2 : Stationary Line-Line Resistance
0
(0, 2)
T1-02
(0702)
Motor Rated Power
Uses the units set in
o1-58 [Motor Power Unit Selection]
to set the motor rated output
power.
Determined by o2-04
(0.00 - 650.00 HP)
T1-03
(0703)
Motor Rated Voltage
Sets the rated voltage (V) of the motor. Enter the base speed voltage for constant output
motors.
Determined by o2-04
(208 V Class: 0.0 - 255.5
V,
480 V Class: 0.0 - 511.0
V)
T1-04
(0704)
Motor Rated Current
Sets the rated current (A) of the motor.
Determined by o2-04
(10% to 200% of the
drive rated current)
T1-05
(0705)
Motor Base Frequency
Sets the base frequency (Hz) of the motor.
60.0 Hz
(0.0 - 400.0 Hz)
T1-06
(0706)
Number of Motor Poles
Sets the number of motor poles.
4
(2 to 120)
T1-07
(0707)
Motor Base Speed
Sets the motor base speed for Auto-Tuning (min
-1
(r/min)).
1750 min
-1
(r/min)
(0 - 24000 min
-1
(r/min))
T1-11
(070B)
Motor Iron Loss
Sets the iron loss for calculating the energy-saving coefficient.
Determined by E2-11 or
E4-11
(0 - 65535 W)
◆
T2: PM Motor Auto-Tuning
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
T2-01
(0750)
PM Auto-Tuning
Selection
Sets the type of Auto-Tuning for PM motors.
0 : Manual Entry w/ Motor Data Sheet
1 : Stationary (Ld, Lq, R)
2 : Stationary (R Only)
4 : Rotational (Ld, Lq, R, back-EMF)
5 : High Frequency Injection
0
(0 - 5)
T2-02
(0751)
PM Motor Code Selection
Enter the PM motor code as specified by the rotation speed and motor output.
FFFF
(0000 - FFFF)
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV
V/f
OLV/PM
OLV/PM
EZOLV