12.2 A: Initialization Parameters
642
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
3330 : 3-Wire Initialization
Sets MFDI terminal S1 to Run, terminal S2 to Stop, and terminal S5 to FWD/REV, and resets all parameters to
default settings.
The drive will not initialize the parameters in
when
A1-03 = 2220, 3330
.
Table 12.2 Parameters that are not Initialized Using a 2-Wire Sequence or a 3-Wire Sequence
No.
Name
A1-00
Language Selection
A1-02
Control Method Selection
A1-07
DriveWorksEZ Function Selection
E1-03
V/f Pattern Selection
E5-01
PM Motor Code Selection
E5-02
PM Motor Rated Power (kW)
E5-03
Motor Rated Current (FLA)
E5-04
PM Motor Pole Count
E5-05
PM Motor Resistance (ohms/phase)
E5-06
PM d-axis Inductance (mH/phase)
E5-07
PM q-axis Inductance (mH/phase)
E5-09
PM Back-EMF Vpeak (mV/(rad/s))
E5-11
Encoder Z-Pulse Offset
E5-24
PM Back-EMF L-L Vrms (mV/rpm)
E5-25
Polarity Estimation Timeout
F6-08
Comm Parameter Reset @Initialize
F6-xx/F7-xx
Communication Option Parameters
Set
F6-08 = 1 [Comm Parameter Reset @Initialize = Reset Back to Factory Default]
to initialize communication option
card parameters.
L8-35
Installation Method Selection
o2-04
Drive Model (KVA) Selection
o2-24
LED Light Function Selection
q1-xx - q8-xx
DriveWorksEZ Parameters
r1-xx
DWEZ Connection 1-20
Note:
•
Set
A1-06 [Application Preset]
to let the drive automatically set the best parameter settings for the selected application. The drive does not
initialize
A1-02
when
A1-03 = 2220, 3330
.
•
When
A1-03 = 2220, 3330
, the drive automatically set
A1-05 [Password Setting] = 0000
. Make sure that you set the password again for
applications where a password is necessary.
■
A1-04: Password
No.
(Hex.)
Name
Description
Default
(Range)
A1-04
(0104)
Password
Entry point for the password set in
A1-05 [Password Setting]
. The user can view the settings of
parameters that are locked without entering the password. Enter the correct password in this
parameter to change parameter settings.
0000
(0000 - 9999)
If the password entered in
A1-04
does not agree with the password setting in
A1-05
, you cannot change these
parameters:
•
A1-01 [Access Level Selection]
•
A1-02 [Control Method Selection]
•
A1-03 [Initialize Parameters]
•
A1-06 [Application Preset]
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Summary of Contents for GA800 Series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...