2.6 Install the Keypad in a Control Panel or Another Device
40
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
2.6
Install the Keypad in a Control Panel or Another Device
◆
Operate the Keypad from a Remote Location
You can remove the keypad from the drive and connect it to a remote control extension cable 3 m (9.8 ft) long to
make operation easier when you cannot access the drive. You can operate a drive that is in a control panel without
opening or closing the control panel door. To order optional accessories, contact Yaskawa or your nearest sales
representative.
Name
Model
Intended Use
Extension Cable
1 m: WV001
3 m: WV003
To connect the keypad and drive.
This option is an RJ-45, 8-pin straight-through UTP CAT5e cable.
Installation Support Set A
900-192-933-001
To attach the keypad to the control panel. This option uses screws.
Installation Support Set B
900-192-933-002
To attach the keypad to the control panel. This option uses nut clamps.
Use this option when weld studs are located in the control panel.
◆
Connect the Keypad from a Remote Location
Use the information in
to install the keypad in the best location for your application.
Table 2.1 Keypad Installation Method
Installation Method
Features
Necessary Tools and Installation Support Sets
Outside of the control panel
Simplified installation is possible. Separate installation
support sets are not necessary.
Phillips screwdriver #2 (M3)
Inside of the control panel
Keypad does not extend farther than the front of the control
panel.
•
Phillips screwdriver #2 (M3, M4)
•
Installation support set A (for mounting with screws,
model: 900-192-933-001)
•
Phillips screwdriver #2 (M3)
•
Wrench (M4)
•
Installation support set B (for mounting with nut clamp,
model: 900-192-933-002)
Note:
Installation support sets are sold separately. If there are weld studs inside the control panel, use installation support set B. Contact Yaskawa
or your nearest sales representative to make an order.
NOTICE:
Do not let unwanted objects, for example metal shavings or wire clippings, fall into the drive during drive installation. Put a
temporary cover over the drive during installation. Remove the temporary cover before start-up. Unwanted objects inside of the
drive can cause damage to the drive.
■
External Dimensions of Keypad
Figure 2.10 Exterior and Mounting Dimensions
Summary of Contents for GA800 Series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Page 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...