YASKAWA
TOEPYAIGA5002A GA500 Programming
179
■
b3-33: Speed Search during Uv Selection
No.
(Hex.)
Name
Description
Default
(Range)
b3-33
(0B3F)
Expert
Speed Search during Uv
Selection
Sets the function that starts Speed Search at start-up if the drive detects a
Uv [Undervoltage]
when it
receives a Run command.
1
(0, 1)
Set these three parameters as shown to enable
b3-33
:
•
L2-01 = 1, 2 [Power Loss Ride Through Select = Enabled for L2-02 Time, Enabled while CPU Power Active]
•
b3-01 = 1 [Speed Search at Start Selection = Enabled]
•
b1-03 = 1 [Stopping Method Selection = Coast to Stop]
0 : Disabled
1 : Enabled
■
b3-54: Search Time
No.
(Hex.)
Name
Description
Default
(Range)
b3-54
(3123)
Search Time
Sets the length of time that the drive will run Speed Search.
400 ms
(10 - 2000 ms)
If you set this parameter too low, Speed Search will not operate correctly.
If the drive detects
oC [Overcurrent]
immediately after Speed Search Starts:
•
Increase the value of
L2-03 [Minimum Baseblock Time]
and decrease the motor speed you use to start Speed
Search.
•
Increases the setting value of
b3-08 [Speed Estimation ACR P Gain]
.
•
Increase the value of
b3-54
.
If the drive detects
oC
or
ov [DC Bus Overvoltage]
during Speed Search, increase the value of
b3-08
.
■
b3-55: Current Increment Time
No.
(Hex.)
Name
Description
Default
(Range)
b3-55
(3124)
Expert
Current Increment Time
Sets the length of time that the drive will increase the current from zero current to the setting value of
b3-06 [Speed Estimation Current Level 1]
.
10 ms
(10 - 2000 ms)
Gradually increase the setting value when a large quantity of current flows after speed search starts. If you set this
value too high, speed search will not operate correctly.
■
b3-56: InverseRotationSearch WaitTime
No.
(Hex.)
Name
Description
Default
(Range)
b3-56
(3126)
InverseRotationSearch
WaitTime
Sets the wait time until the drive starts inverse rotation search after it completes forward search when
you do inverse rotation search during Current Detection Speed Search.
Determined by o2-04
(0.1 - 5.0 s)
■
b3-61: Initial Pole Detection Gain
No.
(Hex.)
Name
Description
Default
(Range)
b3-61
(1B96)
Expert
Initial Pole Detection
Response Gain
Sets the responsiveness for initial motor magnetic pole calculation when
A1-02 = 6 [Control Method
Selection = AOLV/PM]
. Set
b3-61 > 0.0
for an ordinary IPM motor.
5.0
(-20.0 - +20.0)
Used when
n8-35 = 1 [Initial Pole Detection Method = High Frequency Injection]
. Sets the responsiveness for initial
motor magnetic pole calculation. Set this parameter to a positive value for an ordinary monitor. When you use High
Frequency injection Tuning, it will automatically set this parameter.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Summary of Contents for GA500 series
Page 2: ...This Page Intentionally Blank 2 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 456: ...2 12 T Auto Tuning 456 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 488: ...3 8 Test Run Checklist 488 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 494: ...4 3 Remove and Reattach the Keypad 494 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 514: ...5 6 Connect the Drive to a PC 514 YASKAWA TOEPYAIGA5002A GA500 Programming...
Page 525: ...YASKAWA TOEPYAIGA5002A GA500 Programming 525...