11.11 o: Keypad-Related Settings
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
799
■
o5-08: Log Monitor Data 6
No.
(Hex.)
Name
Description
Default
(Setting Range)
o5-08
(1558)
RUN
Log Monitor Data 6
Sets the data log monitor. This parameter is only available when using an LCD keypad.
000
(000, 101 - 999)
Note:
Set the
U monitor
number you will log.
For example, to display
U1-01 [Frequency Reference]
, set
o5-08 = 101
. When it is not necessary to set a data log monitor, set
o5-08 =
000
.
■
o5-09: Log Monitor Data 7
No.
(Hex.)
Name
Description
Default
(Range)
o5-09
(1559)
RUN
Log Monitor Data 7
Sets the data log monitor. This parameter is only available when using an LCD keypad.
000
(000, 101 - 999)
Note:
Set the
U monitor
number you will log.
For example, to show
U1-01 [Frequency Reference]
, set
o5-09 = 101
. When it is not necessary to set data log monitor, set this
parameter to
000
.
■
o5-10: Log Monitor Data 8
No.
(Hex.)
Name
Description
Default
(Range)
o5-10
(155A)
RUN
Log Monitor Data 8
Sets the data log monitor. This parameter is only available when using an LCD keypad.
000
(000, 101 - 999)
Note:
Sets the number of the
U monitor
you will log.
For example, to show
U1-01 [Frequency Reference]
, set
o5-10 = 101
. When it is not necessary to set data log monitors, set this
parameter to
000
. You cannot select
U2 monitor [Fault Trace]
or
U3 Monitor [Fault History]
.
■
o5-11: Log Monitor Data 9
No.
(Hex.)
Name
Description
Default
(Range)
o5-11
(155B)
RUN
Log Monitor Data 9
Sets the data log monitor. This parameter is only available when using an LCD keypad.
000
(000, 101 - 999)
Note:
Sets the number of the
U monitor
you will log.
For example, to show
U1-01 [Frequency Reference]
, set
o5-11 = 101
. When it is not necessary to set data log monitors, set this
parameter to
000
. You cannot select
U2 monitor [Fault Trace]
or
U3 Monitor [Fault History]
.
■
o5-12: Log Monitor Data 10
No.
(Hex.)
Name
Description
Default
(Range)
o5-12
(155C)
RUN
Log Monitor Data 10
Sets the data log monitor. This parameter is only available when using an LCD keypad.
000
(000, 101 - 999)
Note:
Sets the number of the
U monitor
you will log.
For example, to show
U1-01 [Frequency Reference]
, set
o5-12 = 101
. When it is not necessary to set data log monitors, set this
parameter to
000
. You cannot select
U2 monitor [Fault Trace]
or
U3 Monitor [Fault History]
.
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Page 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...