Model
2001
2002
2004
2006
Maximum Applicable Motor Output (kW)
HD
0.1
0.25
0.55
1.1
ND
0.18
0.37
0.75
1.1
Maximum Applicable Motor Output (HP)
HD
1/6
1/4
1/2
1
ND
1/6
1/4
3/4
1.5
Input
Rated Input Current (A)
HD
0.7
1.5
2.9
5.8
ND
1.1
1.9
3.9
7.3
Output
Rated Output Capacity
(kVA)
HD
0.3
0.6
1.1
1.9
ND
0.5
0.7
1.3
2.3
Rated Output Current
(A)
HD
0.8
1.6
3.0
5.0
ND
1.2
1.9
3.5
6
Overload Tolerance
•
HD: 150% of the rated output current for 60 seconds. The permitted frequency of overload is
once every 10 minutes.
•
ND: 110% of the rated output current for 60 seconds. The permitted frequency of overload is
once every 10 minutes.
Note:
Derating may be necessary for applications that start and stop frequently.
Carrier Frequency
HD: 10 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 15 kHz maximum.
Maximum Output Voltage
Three-phase 200 V to 240 V
Note:
The maximum output voltage is proportional to the input voltage.
Maximum Output Frequency
•
EZOLV: 120 Hz
•
AOLV/PM: 270 Hz
•
V/f, OLV, OLV/PM: 590 Hz
Measures for
Harmonics
DC reactor
External options
Braking Device
Braking Transistor
Standard internal characteristics
EMC Filter
EMC Filter
IEC61800-3
Factory option
Models 2xxxE: Category C3 (Conducted emission)
Power Supply
Rated Voltage/Rated Frequency
•
Three-phase AC power supply 200 V to 240 V at 50/60 Hz
•
DC power supply 270 V to 340 V
Permitted Voltage Fluctuation
-15% to +10%
Permitted Frequency Fluctuation
±5%
Input Power (kVA)
HD
0.3
0.7
1.3
2.7
ND
0.5
1.2
1.8
3.3
*1
The maximum applicable motor output complies with 208 V motor ratings as specified in NEC Table 430.250. The rated output
current of the drive output amps must be equal to or more than the motor rated current.
*2
The maximum applicable motor output is based on 4-pole, general-purpose 220 V motor ratings. The rated output current of the drive
output amps must be equal to or more than the motor rated current.
*3
The rated output capacity is calculated with a rated output voltage of 220 V.
Table 10.3 Ratings (Three-Phase 200 V Class)
Model
2010
2012
2021
2030
2042
2056
2070
2082
Maximum Applicable
Motor Output (kW)
HD
1.5
2.2
4.0
5.5
7.5
11
15
18.5
ND
2.2
3
5.5
7.5
11
15
18.5
22
Maximum Applicable
Motor Output (HP)
HD
2
3
5
7.5
10
15
20
25
ND
3
4
5
10
10
20
25
30
Input
Rated Input
Current (A)
HD
7.5
11
18.9
24
37
52
68
96
ND
10.8
13.9
24
37
52
68
80
114
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...