![YASKAWA CIPR-GA50C series Technical Manual Download Page 239](http://html2.mh-extra.com/html/yaskawa/cipr-ga50c-series/cipr-ga50c-series_technical-manual_3241765239.webp)
7.3 List of Fault, Minor Fault, Alarm, and Error Codes
YASKAWA
SIEPC71061753A GA500 Technical Manual
239
7.3
List of Fault, Minor Fault, Alarm, and Error Codes
shows the possible fault, minor fault, alarm, and error codes.
The display codes are in alphabetical order. Search the table for the code shown on the keypad, and identify its
causes and possible solutions.
Note:
The number in parentheses adjacent to the code in the table identifies the fault code or minor fault code (hex. number) that was read
during MEMOBUS/Modbus communications.
Example: AEr (0032)
Table 7.2 List of Fault, Minor Fault, Alarm, and Error Codes
Display (Hex.)
Name
ALM LED
Type
Ref.
AEr (0032)
Station Address Setting Error
Flashing
Alarm
bAT (0085)
Keypad Battery Low Voltage
Flashing
Alarm
bAT (0402)
Keypad Battery Low Voltage
Illuminated
Fault
bb (0008)
Baseblock
Flashing
An alarm
bCE (008A)
Bluetooth Communication Error
Flashing
Alarm
bCE (0416)
Bluetooth Communication Fault
Illuminated
Fault
boL (0045)
Braking Transistor Overload
Flashing
Alarm
boL (004F)
BrakingTransistor Overload Fault
Illuminated
Fault
bUS (0015)
Option Communication Error
Flashing
Alarm
bUS (0022)
Option Communication Error
Illuminated
Fault
CALL (001D)
Serial Comm Transmission Error
Flashing
Alarm
CE (0014)
Modbus Communication Error
Flashing
Alarm
CE (0021)
Modbus Communication Error
Illuminated
Fault
CF (0025)
Control Fault
Illuminated
Fault
CoF (0046)
Current Offset Fault
Illuminated
Fault
CP1 (0087)
Comparator 1 Limit Error
Flashing
Alarm
CP1 (0414)
Comparator 1 Limit Error
Illuminated
Fault
CP2 (0088)
Comparator 2 Limit Error
Flashing
Alarm
CP2 (0415)
Comparator 2 Limit Error
Illuminated
Fault
CPEr
Control Mode Mismatch
-
Backup Function Runtime Errors
CPF00, CPF01
CPF02, CPF03 (0083, 0084)
CPF08 (0089)
CPF11 - CPF14 (008C - 008F)
CPF16 - CPF24 (0091 - 0099)
CPF38 (00A7)
Control Circuit Error
Illuminated
Fault
CPF06 (0087)
EEPROM Memory Data Error
Illuminated
Fault
CPyE
Error Writing Data
-
Backup Function Runtime Errors
CrST
Remove RUN Command to Reset
Flashing
Not an alarm.
CSEr
Control Mode Mismatch
-
Backup Function Runtime Errors
CyC (0033)
MECHATROLINK CommCycleSettingErr
Flashing
Alarm
CyPo (0029)
Cycle Power to Accept Changes
Flashing
Alarm
dCE1 (041A)
Communication Error1
Illuminated
Fault
dCE2 (041B)
Communication Error2
Illuminated
Fault
dEv (0011)
Speed Deviation
Flashing
Alarm
dEv (0019)
Speed Deviation
Illuminated
Fault
dFPS
Drive Model Mismatch
-
Backup Function Runtime Errors
dnE (002A)
Drive Disabled
Flashing
Alarm
dv7 (005B)
Polarity Judge Timeout
Illuminated
Fault
Summary of Contents for CIPR-GA50C series
Page 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 12: ...12 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 44: ...2 9 Installation Methods 44 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 110: ...3 17 Motor Application Precautions 110 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 150: ...4 12 Test Run Checklist 150 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 156: ...5 2 European Standards 156 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 158: ...5 2 European Standards 158 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 288: ...7 10 Troubleshooting Without Fault Display 288 YASKAWA SIEPC71061753A GA500 Technical Manual...
Page 306: ...8 6 Storage Guidelines 306 YASKAWA SIEPC71061753A GA500 Technical Manual...