7 Troubleshooting
YASKAWA Electric TOEP C710606 27 AC Drive - J1000 Quick Start Guide
EN29
ENGLI
S
H
Operator Programing Errors
An Operator Programming Error (OPE) occurs when an inapplicable parameter is set or an
individual parameter setting is inappropriate. This monitor will display the parameter that is
causing the OPE error.
LED Operator
Display
Cause
Corrective Action
oPE01
Drive capacity and value set to o2-04 do not
match.
Correct the value set to o2-04.
oPE02
Parameters were set outside the allowable setting
range.
Set parameters to the proper values.
oPE03
A contradictory setting is assigned to multi-func-
tion contact inputs H1-01 through to H1-05.
• The same function is assigned to two inputs
(this excludes “External fault” and “Not used”)
• Input functions which require the setting of
other input functions were set alone.
• Input functions that are not allowed to be used
simultaneously have been set.
• Fix any incorrect settings.
• Refer to the instruction manual for more details.
oPE05
No option unit is installed and one of the follow-
ing is true:
• b1-01=2 or 3
• b1-02=2
• Install the required option unit.
• Correct the values set to b1-01 and b1-02.
oPE10
The V/f pattern setting is incorrect.
• Check the V/f pattern settings.
• Refer to the instruction manual for more details.