WIRELESS REMOTE
Wireless remote starting is only possible within 78’ (24 m) of the generator.

Do not attempt to adjust the carburetor choke. The remote system will automatically close

and open the choke.

1. Make certain the generator is on a flat, level surface.

2. Turn off all electrical loads connected to the generator. Never start or stop the generator

     with electrical devices plugged in and turned on.

3. Turn the fuel valve to the “ON” position.

4. Press the battery switch to “ON”.

5. Press the engine switch to “ON”. 

  • WIRELESS REMOTE START: press and release the “START” button on the handheld 

remote control device. DO NOT hold the button down, only press the button once. The 

engine will attempt to start six times.

A safety feature is provided which delays the electrical power availability during starting

mode. The delay lasts for approximately 15 seconds. The delay is provided to prevent

damage to the generator if electrical loads are inadvertently turned on during engine startup.
When the battery switch is in the “ON” position, the switch will light up if the battery is

sending out a charge. If the switch does not light up while in the “ON” position, check that the

battery connection is still good.

ELECTRIC START AND RECOIL START
1. Make certain the generator is on a flat, level surface.

2. Turn off all electrical loads connected to the generator. Never start or stop the generator

     with electrical devices plugged in and turned on.

3. Turn the fuel valve to the “ON” position.

4. Press the ignition switch to “ON”.

5. Move the choke lever to the “CHOKE” position.

  • ELECTRIC START: Press the battery switch to “ON.” Press and hold the ignition 

switch to the “START” position. Release as the engine begins to roll over. If the engine 

fails to start within five seconds, release the switch and wait at least ten seconds before 

attempting to start the engine again.

  • RECOIL START: Pull the starter cord slowly until resistance is felt and then pull 

rapidly.

6. Do not over-choke. As as soon as engine starts, move the choke lever to the “RUN”

    position.

Keep choke lever in “CHOKE” position for only 1 push cycle of the ignition button or 1 pull 

of the recoil starter. After first pull, move  choke lever to the “RUN” position for up to the 

next 3 pulls of the recoil starter. Too much choke leads to spark plug fouling/engine flooding 

due to the lack of incoming air. This will cause the engine not to start.

If the engine starts but does not continue to run make certain that the generator is on a flat,

level surface. The engine is equipped with a low oil sensor that will prevent the engine from

running when the oil level falls below a critical threshold.

!

 

  NOTE: The supplied 12 V, 9 Ah battery does re-charge 

while the engine is running, but it is also recommended that 

the battery be fully charged at least once per month.

Oper

ation

Summary of Contents for 055-0361-0

Page 1: ...model number 055 0361 0 contact us 1 866 523 5218 IMPORTANT Read and follow all safety rules and operating instructions before using this product Instruction Manual Portable Generator...

Page 2: ...Table of Contents SPECIFICATIONS 3 KNOW YOUR GENERATOR 4 ASSEMBLY 6 OPERATION 9 SAFETY AND MAINTENANCE 13 EXPLODED VIEW PRODUCT 20 PARTS LIST PRODUCT 21 EXPLODED VIEW ENGINE 26 PARTS LIST ENGINE 27 W...

Page 3: ...19 L Use regular unleaded gasoline with a minimum octane rating of 87 and an ethanol content of less than 10 by volume OIL Use 10W 30 automotive oil Oil capacity is up to 0 6 qt 0 6 L DO NOT OVERFILL...

Page 4: ...7 Recoil Starter 8 Air Filter 7 6 5 4 3 8 1 2 KNOW YOUR GENERATOR Before attempting to assemble or operate your generator please become familiar with the major parts and components Know where to refu...

Page 5: ...30R Outlet 7 5 20R Duplex 2 8 Ground 9 Choke 10 Engine Switch 1 4 3 5 6 7 8 10 9 2 KNOW YOUR GENERATOR Familiarize yourself with the power panel outlets and switches before operation Know how the circ...

Page 6: ...epeat steps 2 4 to attach the second wheel INSTALL THE SUPPORT LEG 1 Attach the support leg to the generator frame with flange bolts M8 x 16 and flange lock nuts M8 2 Tip the generator slowly so that...

Page 7: ...elow 50 of the running watt rating and vary the load occasionally to allow stator windings to heat and cool Adjusting the load will also cause engine speed to vary and help seat piston rings After the...

Page 8: ...en the engine is running or hot DO NOT overfill the fuel tank DO NOT light cigarettes or smoke when filling the fuel tank Pouring fuel too fast through the fuel screen may result in blow back of fuel...

Page 9: ...ed area DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces Carefully consider wind and air currents when positioning generator Do not...

Page 10: ...el surface 2 Turn off all electrical loads connected to the generator Never start or stop the generator with electrical devices plugged in and turned on 3 Turn the fuel valve to the ON position 4 Pres...

Page 11: ...qualified electrician Connections must isolate generator power from utility power and must comply with all applicable laws and codes DO NOT OVERLOAD GENERATOR Capacity Follow these simple steps to cal...

Page 12: ...the operator s panel and shown as Item 3 on page 5 The meter is divided into two separate displays The LCD display on top shows the voltage U frequency H running time R total time and remaining fuel r...

Page 13: ...om your electric utility and notify your utility company before connecting your generator to your power system Sparks can result in fire or electrical shock WHEN SERVICING THE GENERATOR Disconnect the...

Page 14: ...e cap slowly to relieve pressure in the tank Only fill or drain fuel outdoors in a well ventilated area DO NOT pump gas directly into the generator at the gas station Use an approved container to tran...

Page 15: ...lug with a 12 mm socket and extension not included 2 Allow the oil to drain completely 3 Replace the drain plug 4 Remove oil fill cap dipstick to add oil 5 Add 0 6 qt 0 6 L of oil and replace oil fill...

Page 16: ...ster to the muffler 2 Remove the spark arrester screen 3 Carefully remove the carbon deposits from the spark arrester screen with a wire brush 4 Replace the spark arrester if it is damaged 5 Position...

Page 17: ...rs or every season Change oil Clean adjust spark plug Check adjust valve clearance Clean spark arrester Clean fuel tank and filter Every 250 hours Clean combustion chamber Every 3 years Replace fuel l...

Page 18: ...generator for a few minutes so the treated fuel cycles through the fuel system and carburetor 4 Turn the fuel valve to the Off position 5 Let the generator run until fuel starvation has stopped the en...

Page 19: ...be connected to a standard automotive style battery charger for re charging before it can be used Disconnect the Battery 1 Remove the protective cover from the black negative battery lead 2 Disconnec...

Page 20: ...2 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 41 42 43 44 45 46 47 48 49 50 51 52 53 56 57 58 59 60 61 54 52 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 62 82 84 85 86 87 88 89 81...

Page 21: ...n Brush 122 190004 01 1 15 Bolt M5 x 16 1 5783 0516 3 16 Lock Washer 5 1 93 05 3 17 AVR 122 190200 05 1 18 Flange Bolt M5 x 16 1 16674 0516 2 19 Generator End Cover Teal 3145c 152 190003 00 99 1 20 Wa...

Page 22: ...49 Clamp 8 7 x b8 2 06 016 4 50 Fuel Pipe 160 25 mm Fuel Tank to Fuel Valve 122 070011 12 1 51 Decorative Plate Back Cool Gray 11c 124 200800 02 29 1 52 Flange Bolt M6 x 15 Black 1 5789 0615 1 11 53...

Page 23: ...Black 1 5789 0612 1 2 83 Flange Bolt M6 x 8 Black 1 5789 0608 1 1 84 Long Pin Handle 152 200703 04 2 85 Short Pin Handle 152 200703 02 2 86 Circlip 8 1 894 1 08 2 87 Circlip 10 1 894 1 10 2 88 Handle...

Page 24: ...0 930 1 109 20 Amp Circuit Breaker Push Button 5 1210 920 2 110 Lock Nut M4 Flange Black 1 6177 1 04 1 6 111 Over Voltage Protector 5 1810 000 1 112 Charger 5 1820 000 1 113 Screw M5 x 14 1 818 0514 2...

Page 25: ...model no 055 0361 0 contact us 1 866 523 5218 25 Parts List Product This Page Intentionally Left Blank...

Page 26: ...24 31 34 36 39 53 52 45 51 50 49 55 56 57 58 54 60 62 61 63 65 66 67 68 69 70 71 72 74 25 93 94 95 92 91 90 97 78 79 80 82 83 84 85 86 87 88 76 59 12 77 96 33 81 73 106 54 108 109 110 111 107 15 48 1...

Page 27: ...Air Cleaner Black 419c 24 091100 21 30 1 15 Handle Recoil Soft 21 061300 00 1 16 Gasket Air Cleaner 24 130004 20 2 17 Recoil Assembly 22 061000 00 1 18 Air Cleaner Assembly 27 091000 02 1 19 Carbureto...

Page 28: ...32 1 5789 0832 0 8 5 48 Seal Air Cleaner 23 091002 21 1 49 Rod Governor 23 110006 00 1 50 Arm Governor 27 110003 00 1 51 Flange Nut M6 1 6177 06 3 52 Shaft Governor Arm 21 110001 00 1 53 Ignition Coi...

Page 29: ...alve 21 040008 00 1 83 Shaft Rocker Arm 24 040202 00 1 84 Rocker Arm Intake Valve 22 040009 00 2 85 Screw Valve Adjustment 22 040012 00 2 86 Nut M6 0 5 Lock 21 040021 00 2 87 Washer 6 1 97 1 06 2 88 F...

Page 30: ...2 108 Starter Motor Assembly 27 125100 00 1 109 Lock Washer 5 1 93 05 2 110 Flange Bolt M5 16 1 16674 0516 2 111 Relay Starter Remote Control 23 125200 01 1 112 Spring Connecter 81 130010 00 1 113 Con...

Page 31: ...model no 055 0361 0 contact us 1 866 523 5218 31 This Page Intentionally Left Blank Parts List Engine...

Page 32: ...PUT 12 V COMBINATION SWITCH 30 A CIRCUIT BREAKER EARTH TERMINAL RECEIVER MODULE BUTTON PILOT LAMP COMBINATION SW ENGINE BLOCK SPARK PLUG IGNITION COIL CHARGE COIL BATTERY SWITCH STARTER FUSE 10 A CONT...

Page 33: ...crankcase to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Review load and adjust See Power Management Insufficie...

Page 34: ...se parts are warranted to the original purchaser to be free from defects in material and workmanship for a period of one hundred twenty 120 days from the date of retail purchase HOW TO OBTAIN SERVICE...

Page 35: ...ision The use of non original Yardworks service parts may void this warranty if related to the starting problem The warranty excludes special operational conditions that could require more than two el...