background image

Daily maintenance

Main unit maintenance

1.Shut off power supply at maintenance.

2.Turn the seat upward open, press down the button located on the right side of main

   

   unit and pull out the seat. Wipe the stain with a soft damp cloth.

   

   

   

3.Afte

cleaning

,

re-install the seat back to

 

main unit.

Spray nozzle maintenance

Note:

     Do not pour the water on the product at maintenance.

Do the following to clean the wand.

1.Press “rear cleaning” button for a while and wand will come out.

   Wipe the wand clean with a soft damp cloth.

2.Press again  “stop” or “rear cleaning” button, it will stop the 

   cleaning.

Note:

       Do not apply force when pushing or pulling the wand, as this

       may damage the mechanism.

10

Summary of Contents for YX-ETS001

Page 1: ...arefully before installation and keep it available for future maintenance or reference Installation Manual Our company reserves the right of final interpretation for this manual The manual is subject to change without notice ELECTRONIC TOILET SEAT YX ETS001 YX ETS002 ...

Page 2: ...Content Important Safeguards Technical specification Daily maintenance 1 Main unit maintenance 2 Spray nozzle maintenance Troubleshooting Guide Warranty card Others List of packing 3 Inlet filter cleaning Installation instructions 1 Installation dimension 2 Installation of mounting plate 3 Installation and disassembly of main unit 4 Connecting the water supply pipe 4 Tank anti freezing and anti ba...

Page 3: ... the power plug must be switched off and water supply be shut off WARNING To reduce the risk of burns electrocution fire or injury to persons 1 Close supervision is necessary when this product is used by on or near children or invalids 2 Use this product only for its intended use as described in this manual Do not use attachments not recommended by the manufacturer 3 Never operate this product if ...

Page 4: ...ent into normal room temperature wait for 2 hours until the condensation water is fully volatilized Doing so can prevent the product from electrical short circuit 17 When not using the product over three 3 days drain the water out of the container and pull the elelctrical plug from the wall outlet 18 Stop using the product and shut off the power when product malfunctions please contact the service...

Page 5: ...ature controller Thermal fuse Ground protection Leakage protection device Air burning preventer Heated seat Quiet soft closing device The seat temperature will automatically lower to level 1 in 10 minutes after using Seat sensor emperature sensor Temperature controller T Thermal fuse Intelligent Intellignt often in the off state Buzzeroff during night Container capacity Rating power Rating pressur...

Page 6: ...se Plate Parts Water Supply Assembly Installation paperboard Installtion Manual Warranty Card Warranty Card Installtion Manual Installation paperboard Installtion Manual Warranty Card Installation paperboard Main Unit pcs pcs pcs pcs Base plate 此处更改 ...

Page 7: ...utton Lid Side receiving window Water discharging cover Main unit disassembly button Remote control receiving window Power indicator Energy saving indicator Seat Drying device Base plate Night light Spray nozzle Wand Hole for rear cleaning Hole for ladies front cleaning ...

Page 8: ...c plates flat washers and bolt as per the drawing and tighten the bolts Bolt Washer Plastic plate Base plate Expansion nut Installation paperboard Note Unfold the installation paperboard align the paperboard well fit ceramic bowl from the tip and then insert base plate to the paperboard breach to make sure base plate allign with paperboard breach Tip d The black pin frontward and groove upwards In...

Page 9: ... is heard and pull it out Installation Disassembly Note Before pulling out the washlet release hand from removal button 1 Side inlet Install the 3 way valve onto the toilet then attach the water supply hose and the washlet inlet hose into 3 way valve Connect L shaped end of water supply hose to the washlet inlet connector 2 Bottom inlet Connect water supply on the inlet connector then put supply h...

Page 10: ...water starts to flow into tank and heating will take 3 minutes Insert power plug into power socket NOTE If it s an electric leakage protection plug press protection switch indicator Press electric leakage test button prior to usage protection switch bounces to show that protection function works normally Press the TEST button then RESET button every month to assure proper operation light is on whi...

Page 11: ...en people sit press Power button to stop the function of rear front cleaning or drying When no one sits press Power button to switch between function mode and power save mode 3 If the product is not used for continual 72 hours the water in the tank will automatically discharge for 90 seconds and replaced by fresh water to avoid bacteria Remark 1 When main unit is in functional mode the light of po...

Page 12: ...er cleaning re install the seat back to main unit Spray nozzle maintenance Note Do not pour the water on the product at maintenance Do the following to clean the wand 1 Press rear cleaning button for a while and wand will come out Wipe the wand clean with a soft damp cloth 2 Press again stop or rear cleaning button it will stop the cleaning Note Do not apply force when pushing or pulling the wand ...

Page 13: ... temperature is under zero and electricity is disconnected or user is away for a long time The water inside the tank should be discharged 1 Open the tank cover press the discharge button turn on valve to discharge the water 2 Slightly press the discharge button protruding part to turn off discharging valve and cover Turn on cover Press downward the protruding part Press inward the discharging butt...

Page 14: ...ion mode for 3 minutes No wind out Spray wand cannot retracted Spray wand cannot stretch out Controller cannot display The wind temperature is setted on normal temperature level In standby mode or power save mode Power off Get stuck by impurities Do not sit in sensing area Reverse the polarity of battery Reload the battery Sit right in the sensing area Push back the wand lightly and wait for the p...

Page 15: ...13 Our company ...

Page 16: ...e and color because of products improvement please in kind prevail ASVFAC0428000A 1 3 Hangzhou Netease Yanxuan Trading Co Ltd Add Room 410 No 4 Building No 599 Road Wangshang Binjiang District Hangzhou Zhejiang Province P R China E mail services yanxuan service netease com ...