TROUBLESHOOTING
80
L-N Operation Manual
Indicator Stays On - Key Switch is Turned from Start to ON (START
→
ON)
• Battery indicator stays On
• Faulty alternator
• See authorized Yanmar
industrial engine dealer or
distributor
—
• Engine oil pressure indicator
stays On
• Faulty engine oil pressure
switch
—
Engine Does Not Start
• Starter motor operates but
engine does not start
• No diesel fuel
• Refuel fuel system
• Improper diesel fuel
• Replace with recommended
diesel fuel
• Clogged fuel filter
• Replace fuel filter
Fuel Filter on page 73
• Poor fuel injection
• See authorized Yanmar
industrial engine dealer or
distributor
—
• Compressed air leakage from
intake / exhaust valves
—
• Faulty engine stop solenoid (if
equipped)
—
• Starter motor does not
operate or rotates too slowly
(engine can be turned
manually)
• Battery needs charging
• Check electrolyte, recharge
• Faulty cable connection at
• battery terminals
• Clean terminals, retighten
—
• Faulty starter switch
• See authorized Yanmar
industrial engine dealer or
distributor
—
• Faulty starter motor
—
• Engine cannot be manually
turned
• Inner parts seized or damaged
—
White or Black Exhaust Smoke
• Black exhaust smoke
• Engine overloaded
• Reduce load
—
• Clogged air cleaner element
• Clean element or replace
• Improper diesel fuel
• Replace with recommended
diesel fuel
• Faulty spraying of fuel
injection
• See authorized Yanmar
industrial engine dealer or
distributor
—
• Excessive intake / exhaust
valve clearance
—
SYMPTOM
PROBABLE CAUSE
ACTION
REFER TO