Installation and maintenance of clean water sub-tank (Special order item)
When the temperature of the cooling water inside the clean water tank rises, it
eventually turns to steam and escapes to the outside atmosphere.
If a sub-tank is combined with the clean water tank, steam from the clean water
tank will be restored to hot water, thus considerably reducing the consumption
of cooling water.
It is therefore recommended that a sub-tank be fitted if possible.
Regarding the handling and installation of the sub-tank, take note of the following
points:
1)
Installation of sub-tank
(1) Mount the sub-tank at the same height as the clean water tank.
(2) Ensure that the length of the cooling water tube is no more than 1 m., and
that it does not break.
2)
Maintenance during use
(1) Check that when the cooling water is cold the level is within the specified
range (HIGH: 0.8 liter, LOW: 0.2 liter).
(2) Check that the cooling water pipe is not broken, and also that the holes
are not brocked up.