A05G072
8
7.
COMMON ABNORMAL SITUATIONS AND SOLUTIONS
ITEM SITUATIONS
POSSIBLE CAUSES
SOLUTIONS
1.
Pump stop or
pump can`t
start
No power or incorrect power
Supply power or correct
power source
Magnetic switch damaged
Replace a new one
Fuse/current protector action
Reset or change fuse
Motor coil fail / damaged
Replace a new one
Power cable loosing
Check and reconnect
2.
High temp.
(Motor
temp.>75
℃
)
High viscosity of fluid
Reduce the fluid viscosity
High pressure output
Check reason and correct it
Capacity of inverter too much or
insufficient
Change a suitable one
Frequency of inverter too high
or too low
Set frequency variation range
between 30~60Hz
Output line block or valve closed
Clear block or open valve
Incorrect power source
Change to a correct one
The motor coil insulation is bad
Replace a new motor
Abrasion of bearing or the bad
lubricity
Renew the bearing or improve
the lubricity
High environmental temperature
or bad ventilation
Improve temperature and
ventilation of the environment
3.
No fluid
output
Motor is stop
Check with ITEM 1.
Blocking of the inlet pipe (or
foot valve)
Eliminate from blocking
Damage of the diaphragm
Replace with a new one
Flow regulator was set too low
(stroke <1.0mm)
Adjust to proper setting
Drive mechanism malfunction
Renew the drive mechanism
(Return to factory)
4.
Flow rate
reduce
obviously
Blocking of the inlet pipe (or
foot valve)
Eliminate from blocking
Fluid viscosity become high
Reduce fluid viscosity
Leakage of the pipe
Patch up the leakage
Drain valve not close
Close drain valve
Gas accumulates in pump head
Purge gas through drain valve
5.
Abnormal
noise or
vibration
Power source problem (incorrect
or disconnection of power or
lack of a phase)
Check and reinstall power
source
Abrasion of bearing or the bad
lubricity
Renew the bearing (Return to
factory)or improve the
lubricity
Abrasion of gears of the reducer
Replace with a new reducer
(Return to factory)
Eccentric mechanism bearing
failure
Replace with a new one
(Return to factory)
6.
Looseness of fix-screws
Fix the loosen screws