background image

A05G072 

7.

 

COMMON ABNORMAL SITUATIONS AND SOLUTIONS

 

ITEM  SITUATIONS 

POSSIBLE CAUSES 

SOLUTIONS 

1. 

Pump stop or 
pump can`t 
start 

No power or incorrect power   

Supply power or correct 
power source 

Magnetic switch damaged 

Replace a new one 

Fuse/current protector action 

Reset or change fuse 

Motor coil fail / damaged 

Replace a new one 

Power cable loosing 

Check and reconnect 

2. 

High temp. 

(Motor 
temp.>75

High viscosity of fluid 

Reduce the fluid viscosity 

High pressure output   

Check reason and correct it 

Capacity of inverter too much or 
insufficient 

Change a suitable one 

Frequency of inverter too high 
or too low 

Set frequency variation range 
between 30~60Hz 

Output line block or valve closed 

Clear block or open valve 

Incorrect power source 

Change to a correct one 

The motor coil insulation is bad

 

Replace a new motor 

Abrasion of bearing or the bad 
lubricity 

Renew the bearing or improve 
the lubricity 

High environmental temperature 
or bad ventilation 

Improve temperature and 
ventilation of the environment   

3. 

No fluid 
output 

 

Motor is stop 

Check with ITEM 1. 

Blocking of the inlet pipe (or 
foot valve) 

Eliminate from blocking 

Damage of the diaphragm 

Replace with a new one 

Flow regulator was set too low 
(stroke <1.0mm) 

Adjust to proper setting   

Drive mechanism malfunction 

Renew the drive mechanism 
(Return to factory) 

4. 

Flow rate 
reduce 
obviously

 

Blocking of the inlet pipe (or 
foot valve) 

Eliminate from blocking 

Fluid viscosity become high 

Reduce fluid viscosity   

Leakage of the pipe 

Patch up the leakage 

Drain valve not close 

Close drain valve   

Gas accumulates in pump head 

Purge gas through drain valve 

5. 

Abnormal 
noise or 
vibration

 

Power source problem (incorrect 
or disconnection of power or 
lack of a phase) 

Check and reinstall power 
source 

Abrasion of bearing or the bad 
lubricity 

Renew the bearing (Return to 
factory)or improve the 
lubricity 

Abrasion of gears of the reducer 

Replace with a new reducer 
(Return to factory) 

Eccentric mechanism bearing 
failure 

Replace with a new one 
(Return to factory) 

6. 

 

Looseness of fix-screws 

Fix the loosen screws 

Summary of Contents for HP Series

Page 1: ...A05G072 1 ANGTECH ENGLISH 20 03 HP SERIES DIAPHRAGM METERING PUMP FOR MODEL HP 1315 1330 1715 1730 YANGTECH TECHNOLOGY CO LTD Taiwan O P E R A T I O N M A N U A L...

Page 2: ...th the power source and connection are correct before use If use a inverter as power supply the frequency variation range should between 30 60Hz Frequency below 30Hz for a long period of time may caus...

Page 3: ...List Material Code AC AF BS VS SS Application Acid Oxidative Acid Base Thick Solvent 1 Pump Head PVC PTFE PVC PVC SUS304 2 Valve Ball Ceramic Ceramic SUS316 SUS316 SUS316 3 Valve Seat PVC PTFE PVC PV...

Page 4: ...base HP3 26 1 set SUS304 2 Pipe injector Anti Siphon include 1 piece 1 0 PVC Glue on type If Optional items are necessary purchase them in the same order 4 INSTALLATION Conform both the power source...

Page 5: ...h drain valve Output pipe may install following devices to solve some problems Pulse reducer To reduce pipe vibration especially pipe is long thin plenty of elbows Pressure gauge To monitor output pip...

Page 6: ...o suck fluid into pump spontaneously In this case a check valve should be installed Sucking head is not a guarantee To change the discharge rate loosen the fix nut then turn the flow regulator knob wh...

Page 7: ...luid H2O Temperature 25 Power Source 220V 3 60Hz Stroke length 100 12mm Pulse rate 200 Pulses min Pressure unit kg cm2 Note 1 Pipe altitude length number of valves liquid viscosity pressure all these...

Page 8: ...perature or bad ventilation Improve temperature and ventilation of the environment 3 No fluid output Motor is stop Check with ITEM 1 Blocking of the inlet pipe or foot valve Eliminate from blocking Da...

Page 9: ...ors are clean and tight regularly Avoid the chemical splash on the pump If do wash off immediately Check for abnormal noise temperature higher then 70 leakage regularly Solve them according to the COM...

Page 10: ...A05G072 10 9 CONNECTOR DISASSEMBLE ILLUSTRATION...

Page 11: ...9 3 3 15 7 13 1 7 8 6 5 7 0 cm2 7 6 6 3 3 8 3 2 7 3 6 1 10 0 3 5 2 9 2 Pressure Max kg cm2 PVC PVDF 7 0 10 0 5 0 7 0 SUS 12 0 3 Stroke Length mm 0 0 12 0 4 Pulse Rate pulse min 116 97 58 48 116 97 58...

Page 12: ...A05G072 12 YANGTECH YANGTECH TECHNOLOGY CO LTD Taiwan...

Reviews: