 Note : when the motor is started for the very first time, it will require a number of attempts to start 

until the fuel has travelled from the tank to the motor.  

 

 

 

 

 

 

6.

 

once you hear the motor operating. Return the choke lever back to the right 

hand side position. This positin will switch the choke ‘’OFF’’. 

 

 

Under the following conditions the generator must be stop:  

1. When the motor rotary speed changes   

2. When the electrical power is decreasing  

3. When connected appliances are overheated  

4. When sparks occur   

5. When plugs are damaged   

6. In case of misfire   

7. In case of high vibration   

8. When flames or smoke appear  

9. In rain or stormy weather 

 

AC CIRCUIT BREAKER  

In case of short-circuit or over-load of generator, AC Circuit breaker will cut off the circuit. Once the 

AC circuit breaker has automatically switched to “OFF” position, please check the connected 

electric appliance before switching it back “on” position.  

 

AC and DC CIRCUIT PROTECTORS 

In case of short-circuit or over-load of generator, circuit protector will cut off 

the circuit. Once the circuit protector has automatically switched to “OFF” 

position, please check the connected electric appliance before switching it 

back “on” position.  

 

AC applications 

1. Start the engine and allow the motor to run for a couple of minutes to warm up before 

connecting any appliance to the generator.  

2. Confirm that the appliance is switched off, and then plug it in the socket in generator. 

WARNING! 

Faulty appliances or power cords can create a potential electrical shock.  

It is highly recommended to have a 30 mA circuit protector connected to the generator at all 

times.  

Never use the appliance have the power exceed the maximum rating of the generator.  

 

DC APPLICATIONS  

The DC Output should only be used for recharging 12-volt automotive lead acid type batteries. 

And do not charge batteries while they are connected to a vehicle. Make sure they have been 

totally disconnected before recharging.  

 

When charging a battery the following instructions need to be followed: 

1.

 

disconnect the orginal leads from the battery.  

2.

 

fully loosen the battery caps 

3.

 

start the generator and allow the motor to run for a couple of minutes to warm up before 

connecting any apparatus to the generator.  

Note: Do not short circuit two clips of the DC Cable. Take extra care to connect the wire to battery.  

4.

 

connect the supplied DC Plug lead into the DC Socket and connect the red lead of battery 

charging cable to the positive (+) battery terminal and the black lead to the negative (-) 

battery terminal. 

5.

 

press the DC Circuit protector to reset if the DC supply had previously been overloaded.  

Summary of Contents for G800-2T

Page 1: ...Generatore G800 2T Gasoline generator G800 2T Generador G800 2T cod 94716 Manuale istruzioni Instruction manual Manual de instrucciones ITALIANO ENGLISH ESPA OL Distribuzione PADOVA ITALY...

Page 2: ...rre alla pioggia L impianto di scarico e i gas di scarico sono surriscaldati Rischio d infortunio a causa di elementi mobili Mantenere sempre un adeguata distanza di sicurezza L avvio del motore gener...

Page 3: ...come risultato di operazioni in zone regolamentate sar necessario ridurre la potenza h Ridurre la potenza necessario se si utilizza la macchina in condizioni di temperatura o umidit elevata o in quot...

Page 4: ...accidentali 4 Manutenzione e stoccaggio a Mantenere serrati tutti i dadi i bulloni e le viti per il buon funzionamento dell apparecchio b Non stoccare mai l apparecchio con il serbatoio contenente car...

Page 5: ...tore 1 2kw Consumo specifico di carburante alla potenza max motore 554 g kWh Consumo di carburante alla potenza max motore 0 67kg h Livello di pressione sonora LwA 94dB A Tipo di carburatore Chuang xi...

Page 6: ...aggio della maniglia Posizionare innanzitutto le 2 guarnizioni della maniglia in dotazione sui fori del serbatoio quindi procedere posizionando la maniglia sulle guarnizioni e accertarsi che i 2 fori...

Page 7: ...dal tubo di uscita posteriore del foro di scarico carburante Utilizzare carburante con almeno 90 ottani Raccomandiamo benzina senza piombo poich lascia meno residui all interno del motore e sulla cand...

Page 8: ...rcuito o sovraccarico del generatore l interruttore disgiuntore interrompe il circuito Dopo che l interruttore disgiuntore avr azionato automaticamente la posizione OFF controllare l apparecchio elett...

Page 9: ...izione off MANUTENZIONE Una buona manutenzione essenziale per un funzionamento senza problemi Riduce inoltre l inquinamento atmosferico Il programma di manutenzione serve a mantenere il generatore nel...

Page 10: ...eneratore senza filtro dell aria CANDELA D ACCENSIONE CANDELA CONSIGLIATA F6TC Per assicurare un corretto funzionamento del motore la candela deve avere un traferro corretto e non presentare depositi...

Page 11: ...5 10 minuti e riprovare seguendo le istruzioni In alternativa se l arricchitore sulla posizione Start metterlo su Run e riprovare 8 Carburante vecchio 8 Svuotare e sostituire Alimentazione CA Nessuna...

Page 12: ...re su una superficie piana e stabile Riscaldare il motore per vari minuti quindi arrestarlo 2 Allentare la vite di scarico del carburatore e scaricare il carburante in un contenitore 3 Serrare la vite...

Page 13: ...flying parts Always maintain a sufficiently safe distance Start engine creates sparking Sparking can ignite nearby flammable gases Engines give off carbon monoxide an odorless colorless poison gas Bre...

Page 14: ...cessary reduction in power due to use in higher temperatures altitudes and humidity as below conditions 1 Max Working Temperature 40 C 2 Max altitudes 1000 m 3 Max humidity 95 3 Operation a Do not ope...

Page 15: ...rage a Keep all nuts bolts and screws tight to be sure the equipment is in safe working condition b Never store the equipment with petrol in the tank inside a building where fumes can reach an open fl...

Page 16: ...wer 0 67kg h A weighted emission sound pressure level LwA 94dB A Type of carburetor Chuang xin IE45F Type of ignition switch KCD4 Type of silencer N A Type of spark plug LD F6TC Mix 100mL of oil with...

Page 17: ...nk Screw the handle onto the petrol tank using the 2 screws provided with the unit Ensure the flat washers are fitted under the heads of the screws Mixing the fuel 1 The generator uses unleaded fuel a...

Page 18: ...life cycle of the exhaust system Never use old or dirty petrol or oil petrol mixtures Avoid contamination with dirt or water in the tank Occasionally ignition knocking or clanging can be heard with h...

Page 19: ...ations 1 Start the engine and allow the motor to run for a couple of minutes to warm up before connecting any appliance to the generator 2 Confirm that the appliance is switched off and then plug it i...

Page 20: ...justment schedule is to keep the generator in the best operating condition Turn off the engine before performing any maintenance If the engine must be run make sure the area is well ventilated The exh...

Page 21: ...the spark plug gap The acceptable gap should be between 0 6 0 7mm 8 Install reinstall the spark plug carefully by hand 9 Once the spark plug has been seated tighten with the spark plug wrench 10 Reins...

Page 22: ...ripping 1 overload 1 reduce load 2 faulty cords or equipment 2 Check for damaged bare or frayed wires on equipment Replace 3 Incorrect cables used 3 Check to make sure you are using the DC Cables coul...

Page 23: ...the engine for several minutes and then stop it 3 Loosen the fuel drain screw on carburetor and drain fuel into a container thoroughly 4 Tighten fuel drain screw Store the machine operating instructio...

Page 24: ...a m quina a la lluvia La instalaci n de descarga y el gas de descarga se sobrecalientan Riesgo de infortunio a causa de elementos m viles Mantener siempre una adecuada distancia de seguridad Cuando el...

Page 25: ...orado por ejemplo como resultado de operaciones en zonas reglamentadas ser necesario reducir la potencia h Reducir la potencia es necesario si se utiliza la m quina en condiciones de temperatura o hum...

Page 26: ...e encendido para evitar arranques accidentales 4 Mantenimiento y almacenamiento a Mantener apretados todas las tuercas los pernos y los tornillos para garantizar el buen funcionamiento del equipo b No...

Page 27: ...motor 3000 200 min Velocidad del motor con par m ximo 2500 min Potencia m xima del motor 1 2kw Consumo espec fico de combustible a la potencia m xima del motor 554 g kWh Consumo de combustible a la po...

Page 28: ...corriente alterna FUNCIONAMIENTO Preparaci n del generador Leer con atenci n las instrucciones y controlar el generador antes de usarlo Montaje de la empu adura Colocar primero las 2 guarniciones de...

Page 29: ...do horario ADVERTENCIA No efectuar el rellenado con el motor encendido o sobrecalentado Asegurarse de que el combustible no se derrame por el tubo de salida posterior del agujero de descarga del combu...

Page 30: ...o Despu s de que el interruptor disyuntor de CA ha accionado autom ticamente la posici n OFF controlar el equipo el ctrico conectado antes de volverlo a colocar en la posici n ON PROTECCIONES DE CIRCU...

Page 31: ...ter as y la toma de 230V de CA No obstante cuando el generador funciona cerca del l mite m ximo de carga como pudiera sobrecargarse y en tal caso la carga de CA se debe reducir o desconectar Parada de...

Page 32: ...Extraer el filtro de aire 3 Lavar el filtro con un solvente 4 Lubricar el filtro con aceite para motores 5 Comprimir el filtro eliminando el aceite en exceso 6 Volver a colocar el filtro ADVERTENCIA...

Page 33: ...as Aver a Causa posible Soluci n El motor no arranca 1 Nivel de combustible aceite bajo 1 A adir la mezcla de combustible aceite 2 Interruptor de encendido en OFF 2 Poner en ON 3 Buj a de encendido d...

Page 34: ...lo contrario limpiarlo secarlo y volverlo a instalar 5 Filtro de combustible obstruido 5 El filtro de combustible interno pudiera estar obstruido contactar la asistencia para que lo sustituya Funciona...

Page 35: ...os y o en la documentaci n de acompa amiento significa que los productos el ctricos y electr nicos utilizados no se deben mezclar con los desechos dom sticos gen ricos Para garantizar un correcto trat...

Page 36: ...ctos 94716 indicado en este manual estan de acuerdo con las Directivas Europeas 2006 42 EC 2014 35 EU 2014 30 EU 2005 88 CE DISTRIBUDOR PARA ESPA A A FORGED TOOL S A Avda Andaluc a s n 18015 Granada S...

Reviews: