background image

 

Thank  you  for  choosing  BM/BO  Series 
Baths from Yamato Scientific Co., Ltd.

 

 

For  proper  equipment  operation,  please 
read  this  instruction  manual  thoroughly 
before  use.  Always  keep  equipment 
documentation safe and close at hand for 
convenient future reference.

 

 

WARNING:

 

Read  instruction  manual  warnings  and 
cautions  carefully  and  completely  before 
proceeding.

 

 

 

Water Bath

 

BM500/510 

Oil Bath

 

BO400/410

 

Instruction Manual 

 

- First Edition -

 

Yamato Scientific America Inc

 

Santa Clara

CA 

 

                                                     

                               

    Printed on recycled paper

 

Summary of Contents for BM510

Page 1: ...hly before use Always keep equipment documentation safe and close at hand for convenient future reference WARNING Read instruction manual warnings and cautions carefully and completely before proceedi...

Page 2: ......

Page 3: ...Constant Temperature Mode 18 Quick Auto Stop Mode 19 Auto Stop Mode 21 Auto Start Mode 23 Overheat Prevention Settings 25 Keypad Lock Function 26 Bath Setting Function 26 Calibration Offset Function 2...

Page 4: ...nded hospitalization and or outpatient treatment Note 2 Minor injury is defined as bodily wounds or electrocution which will not require extended hospitalization or outpatient treatment Note 3 Propert...

Page 5: ...ral Caution Caution Electrical Shock Hazard Caution Burn Hazard Caution Do Not Heat Without Water Caution May Leak Water Caution Water Only Caution Toxic Chemicals Restriction General Restriction No O...

Page 6: ...o overheat and or catch fire DO NOT damage power cable Damaging the power cable by forcibly bending pulling or twisting may cause fire or electric shock to the operator Perform periodic equipment insp...

Page 7: ...torm In the event of a thunderstorm terminate operation and turn off main power switch immediately A direct lightning strike may cause damage to equipment or result in fire or electric shock Power Out...

Page 8: ...dedicated ground terminal for the larger capacity single phase 100V to 120V BM500 and B0400 models Use an outlet with a dedicated ground terminal for the single phase 200V to 240V BM510 and B0410 mode...

Page 9: ...elayed during operation causing a fire or explosion when near flammable or explosive fluids chemicals or gases fumes See List of Hazardous Substances P 40 4 Installation Requirements BO400 and BO410 m...

Page 10: ...y BM500 BO400 100 to 120V AC 12 5A BM510 BO410 200 to 240V AC single phase 6 5A NOTE In the unlikely event that unit does not run after turning power ON inspect whether power supply voltage of the mai...

Page 11: ...g so may cause power cable insulation to overheat melt and or catch fire which may result in electric shock Turn off power switch immediately and disconnect from facility terminal or outlet if power c...

Page 12: ...outdoors Turn power OFF when removing bath container from the main unit Do not heat bath container without water BO400 410 oil bath operation precautions Exercise caution in regard to the following Co...

Page 13: ...iscosity 25 C mm2 s cSt 50 Volatility 150 C 24h 0 3 Viscosity temperature coefficient 0 59 Flash point C 325 Pour point C 50 C Viscosity increase rate 300 C 168h 40 Silicon oil deterioration rate visc...

Page 14: ...e unit for cleaning turn off power switch disconnect the power cable and clean ONLY after confirming that heater and unit have cooled sufficiently Oil supply for BO model water bath Fill with maximum...

Page 15: ...ront view Removable Bath Container Control Panel Power Cable Receptacle Main Unit heat resistant ABS resin Interface for operating bath in combination with rotary evaporator model RE600 800 Connection...

Page 16: ...or one second Operation Lamp Lights during constant temperature operation Flashes during timed operation TIMER Key TIMER Setting key for quick auto stop auto stop and auto start operation modes MAINTE...

Page 17: ...nit Only available when RE600 800 rotary evaporator unit is connected StoP Stop Displayed to select bath auto stop mode Only available when RE600 80 rotary evaporator unit is connected KEEP Keep Displ...

Page 18: ...t Mode Press TIMER key twice while unit is in standby Select and set operation time using Press and hold START STOP to start auto start mode 23 BM BO series safety features are outlined in the table b...

Page 19: ...orator unit completes its own operation Select using to keep bath heated when the rotary evaporator unit completes an operation The factory default setting is which disables interface operation Settin...

Page 20: ...TART STOP Press hold 1 sec to stop AS P displayed AStR displayed Press hold 1 sec to start Operation starts when time is up Press hold 4 seconds Select on to lock Select off to unlock TIMER To mainten...

Page 21: ...erature setting the unit interprets this as an overheating event Power is cut to the heater and error 6 is displayed If bath water level becomes too low while unit is running cancel operation before a...

Page 22: ...crease value After three seconds display will revert to current bath temperature standby 3 Start operation Press and hold START STOP Operation begins The operation and HEATER lamps light and temperatu...

Page 23: ...play will automatically revert to temperature reading after 4 seconds To change the setting continue operating until desired temperature is entered Unit will continue operation under new temperature s...

Page 24: ...ree seconds display will revert to current bath temperature standby 3 Set auto stop timer Press TIMER and select AstP The screen displays AstP and timer setting alternately Set auto stop time using 4...

Page 25: ...change the setting continue operating until desired temperature is entered Unit will continue operation under new temperature setting Correcting timer setting Press TIMER during operation to change ti...

Page 26: ...Temperature setting is shown Press to increase value Press to decrease value After three seconds display will revert to current bath temperature standby 3 Set auto start timer Press TIMER and select...

Page 27: ...ill automatically revert to temperature reading after 4 seconds To change the setting continue operating until desired temperature is entered Unit will continue operation under new temperature setting...

Page 28: ...an overheating event Power is cut to the heater and error 6 is displayed If bath water level becomes too low while unit is running cancel operation before adding If overheating prevention devices acti...

Page 29: ...ble supplied with the RE600 800 unit Refer to the VR600 VR800 instruction manual for details Bath operation setting Using signals from to the RE unit vacuum controller this function stops bath complet...

Page 30: ...ion at any temperature When temperature stabilizes measure bath temperature using a temperature recorder or other precision thermometer If control panel temperature reading and manually taken temperat...

Page 31: ...r failure Press and hold TIMER for about four seconds then press it repeatedly until Pon is shown Select on or oFF using On continues operation when power is restored OFF terminates operation when pow...

Page 32: ...diately disconnect power cable from power supply and contact a local dealer or Yamato sales office for assistance Continuing to operate without addressing abnormalities may cause fire or electric shoc...

Page 33: ...ys turn off main power switch and disconnect power cable 5 Use proper bath fluids Using purified or distilled water in BM model water bath is recommended to prevent mineral deposit accumulation Never...

Page 34: ...temperature falls to 45 C or below Do not attempt to dismantle or disassemble unit CAUTION Clean main unit exterior with a soft damp cloth and mild detergent Do not use benzene thinner cleansers or ot...

Page 35: ...ssembling unit as far as is possible in order to separate parts and recycle them in contribution to preserving the global environment Major components and materials comprising BM BO series units are l...

Page 36: ...erature sensor error Temperature sensor faulty or severed from circuit Check replace the sensor Restart to clear error Er06 Overheat Overheating prevention device has been activated by overheating or...

Page 37: ...n display Check whether temperature setting is lower than bath temperature Temperature does not come down Check whether temperature setting is lower than bath temperature Temperature reading too high...

Page 38: ...required for all repairs Model name Serial Number Date year month day of purchase Description of problem in as much detail as possible Guaranteed Supply Period for Repair Parts Guaranteed maximum sup...

Page 39: ...power failure recovery overheat prevention manual return at temperature setting plus 40 C thermal fuse micro switch to detect heating without water oil circuit protector Modes Constant temperature Qu...

Page 40: ...hermal fuse SSR Solid state relay PLANAR Control board TH K thermocouple PIO Display board CN Bath signal connector Symbol Part name MCB Circuit protector T Terminal block H Heater F Thermal fuse SSR...

Page 41: ...fuse SSR Solid state relay PLANAR Control board TH K thermocouple PIO Display board CN Bath signal connector FM Fan Symbol Part name MCB Circuit protector T Terminal block H Heater F Thermal fuse SSR...

Page 42: ...entific BM510 only Part Name Code No Specification Manufacturer Thermal fuse LT00036306 128 C G4A50128C Sakaguchi Dennetsu Heater LT00028683 240V 1440W Yamato Scientific Circuit breaker LT00037119 312...

Page 43: ...and other perchlorate Potassium peroxide Sodium peroxide Barium peroxide and other inorganic peroxide Potassium nitrate Sodium nitrate Ammonium nitrate and other nitrate Sodium chlorite and other chl...

Page 44: ...peration BM Add water set the temperature to 50 C and confirm stability BO Add silicon oil set temperature to 100 C and confirm stability 2 Pre operation Procedures pg 5 4 Operation Procedures pg 15 5...

Page 45: ...e not expressly mandated by this manual Doing so may result in equipment malfunction serious personal injury or death Note Instruction manual descriptions and specifications are subject to change with...

Reviews: