INSP
ADJ
3-28
BATTERY INSPECTION
Charging method using a constant current type charger
This type if battery charger Can not charge the MF battery.
Charging method using a constant-voltage type charger
Measure the open-circuit volt-
age prier to charging.
Connect a charger and AMP
meter to the battery, and start
charging.
Make sure the current is higher
than the standard charging
current written on the battery.
Charge the battery until the
battery’s charging voltage is 15
volts.
Check the open-circuit voltage after hav-
ing left the battery for 30 minutes
after charging.
12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is neces-
sary.
Under 12 V --- Replace the battery.
This type of battery charger Can
not charge the MF battery. A
variable voltage charger is rec-
ommended.
NOTE:
Voltage should be measured 30 min-
utes after the machine is stopped.
NOTE:
Set the charging time at 20 hours
(maximum).
YES
NO
Charger
AMP meter
Volt meter