ELEC
SIGNALLING SYSTEM
7-23
Switch
position
Good
condition
Bad
condition
• Place the main switch on “
f
”.
• Place the switch “
b
” on position “
c
” or
“
d
”.
• Check if there is a voltage (12 V) on the
“Chocolate” or “Dark Green” cable of the
bulb holder connector.
SATISFIES THE
SPECIFIED VALUE
(12 V)
The circuit is in good condition.
4. The oil indicator light “OIL” does not light.
1. Bulb and bulb holder
• Check the bulb and bulb holder for conti-
nuity.
CONTINUITY
2.Oil level switch
• Remove the oil sump oil level switch.
• Connect the pocket tester (
Ω
x1) on the oil
level switch.
Cable (+) of tester
Terminal
Cable (–) of tester
Terminal
• Check the oil level measurer for continuity.
A Vertical
position
x
x
upwards
B Reverse
position
x
x
: Continuity
x: No continuity
GOOD CONDITION
3. Voltage
• Connect the pocket tester (20 V DC) on
the bulb holder connector .
Cable (+) of tester
Gray
Cable (–) of tester
Frame ground
OUTSIDE SPECIFIED VALUE
The connection circuit from the “TURN”
switch to the bulb holder connector is
defective, review.
NO CONTINUITY
Change the bulb and/or bulb receptacle.
POOR CONDITION
Change the oil level switch.