– 19 –
E
QSTS CABLE
1. Measure:
●
Jet thrust nozzle set length
a
,
b
Difference
→
Adjust.
2. Adjust:
●
QSTS cable
NOTE:
If the QSTS cable cannot be properly
adjusted by the cable joint at the QSTS con-
verter end, adjust the cable joint at the jet
pump end so that the same lengths are
obtained.
Measurement steps:
●
Set the control grip in the neutral posi-
tion.
●
Set the jet thrust nozzle in the center
position.
●
Measure the jet thrust nozzle set
length
a
and
b
.
●
If
a
and
b
lengths are not even,
adjust the cable joint.
Adjustment steps:
●
Set the control grip in the neutral posi-
tion.
●
Loosen the locknut
1
.
●
Remove the nut
2
and pivot pin
3
.
●
Set the jet thrust nozzle in the center
position.
●
Turn the cable joint
4
in or out for
adjusting lengths
a
and
b
.
Turn in
Length
b
is increased.
Turn out
Length
a
is increased.
WARNING
The cable joint must be screwed in more
than 8 mm (0.31 in).
●
Connect the cable joint
4
and pivot
pin
3
and tighten the nut
2
.
T
R
.
.
Nut:
4 N • m (0.4 kgf • m, 2.9 ft • lb)
●
Tighten the locknut
1
.
T
R
.
.
Locknut:
3 N • m (0.3 kgf • m, 2.2 ft • lb)