117
Tyros3
2-2-4 Press the [START/STOP] button to start the installation.
2-2-5 When the installations are
fi
nished, the following screen
is displayed on the LCD.
2-2-6 Turn the power off.
3
Verifying the program version
3-1 Turn the power on with the [C2#], [F2] and [G2#] keys
(C2# major chord) pressed and held.
C2#
G2#
F2
POWER
ON / OFF
3-2
“TEST”
display appears, and the test mode starts.
3-3 Press the [TEMPO+] button or turn the [DATA ENTRY]
dial clockwise to display
“001: Version”
.
3-4 Press the [START/STOP] button to display the version of
each data.
3-5 Con
fi
rm that the version of the main program is the same
as the version installed this time.
3-6 Press the [START/STOP] button again to return to the
wait state for test number.
4
Executing the factory set
4-1 Press the [TEMPO–] button or turn the [DATA ENTRY]
dial counterclockwise to display
“094:Factory Set”
.
4-2 Press the [START/STOP] button to execute the factory
set.
4-3
“Factory Set OK”
appears on the LCD.
4-4 Press the [START/STOP] button again to return to the
wait state for test number.
4-5 Press the [TEMPO+] button or turn the [DATA ENTRY]
dial clockwise to display
“063:Test Exit”
.
4-6 Press the [START/STOP] button to reboot the Tyros3.
4-7 When the main screen appears normally, the factory set
is completed. (Occasionally, it might take a few minutes.)
CAUTION:
Do not turn the power off before the main
screen shows up.
4-8 Turn the power off.
5
Ending the program installation
The program installation is completed here.
TROUBLESHOOTING
Q1. Power has been turned off or the USB memory
has been removed during operation.
A1.
It is neccesary to re-installation the program. Perform the
installation procedure from initial step.
Q2. An error message appears on the screen and
installation can not be performed.
A2.
Check the following points.
· Is the USB memory is inserted properly?
· Is not there any dirt on the USB memory terminal?
· Does the USB memory contain the whole renewal data
(program) in the root directory?
· Is not any damage of the data (program) in the USB
memory or the USB memory itself?
· Is the renewal data (program) mactched with the
model?
· Perform reinstallation using another USB memory.
Summary of Contents for Tyros3
Page 50: ...50 Tyros3 DM Circuit Board 2NA WM15450 C C to AJK CN7 to AJK CN1 to LCR CN202 to PNR CN4 N C ...
Page 53: ...53 Tyros3 D D DIMM 168 pin Pattern side Scale 90 100 2NA WM15450 ...
Page 60: ...60 Tyros3 PNC Circuit Board H H G G 1 up down 2 3 4 5 6 7 2NA WM24260 ...
Page 62: ...62 Tyros3 PNR Circuit Board I I to PNL CN4 to DM CN205 2NA WM24240 ...
Page 63: ...63 Tyros3 Component side 2NA WM24240 I I ...
Page 64: ...64 Tyros3 PNR Circuit Board J J 2NA WM24240 ...
Page 65: ...65 Tyros3 Pattern side 2NA WM24240 J J to PNC CN2 ...
Page 68: ...68 Tyros3 PNL Circuit Board K K 2NA WM24250 ...
Page 69: ...69 Tyros3 Scale 85 100 Component side K K to PNR CN2 2NA WM24250 ...
Page 70: ...70 Tyros3 PNL Circuit Board L L to LCL CN5 to SWITCHING POWER SUPPLY CN5 2NA WM24250 ...
Page 71: ...71 Tyros3 Scale 85 100 Pattern side 2NA WM24250 L L to PNLS CN202 to PITCHBEND to MODULATION ...
Page 76: ...76 Tyros3 MK61L Circuit Board Component side O O N C O O P P P P to MKH D CN4 2NAKZ WD80020 3 ...
Page 77: ...77 Tyros3 MK61L Circuit Board Pattern side Q Q 2NAKZ WD80020 3 Q Q R R R R ...