CONFIRMATION OF IDLING CURRENT OF AMP UNIT
●
Right after power is turned on, confirm that the voltage across the terminals of R1152 (SURROUND BACK Rch), R1154
(SURROUND Rch), R1150 (FRONT Rch), R1148 (CENTER), R1149 (FRONT Lch), R1153 (SURROUND Lch), R1151
(SURROUND BACK Lch) are between 0.1 mV and 10.0 mV.
●
If it exceeds 10.0 mV, open (cut off) R1090 (SURROUND BACK Rch), R1092 (SURROUND Rch), R1088 (FRONT Rch),
R1086 (CENTER), R1087 (FRONT Lch), R1091 (SURROUND Lch), R1089 (SURROUND BACK Lch) and reconfirm the
voltage.
Attention
If the measured voltage exceeds 10.0 mV after an amplifier repair, first check for a defective component before cutting
the bias resistor.
●
Confirm that the voltage is 0.2 mV to 15.0 mV after 60 minutes.
Summary of Contents for RX-V667
Page 4: ...4 RX V667 HTR 6063 RX A700 RX V667 HTR 6063 RX A700 HTR 6063 C A models RX A700 U model...
Page 8: ...8 RX V667 HTR 6063 RX A700 RX V667 HTR 6063 RX A700 HTR 6063 A model RX A700 U model...
Page 106: ...RX V667 HTR 6063 RX A700 106 MEMO MEMO...
Page 139: ...RX V667 HTR 6063 RX A700 139 ADVANCED SETUP U model...
Page 140: ...RX V667 HTR 6063 RX A700 140...
Page 141: ...RX V667 HTR 6063 RX A700 141...
Page 142: ...RX V667 HTR 6063 RX A700 142 C R T K A B G f L models...
Page 143: ...RX V667 HTR 6063 RX A700 143...
Page 144: ...RX V667 HTR 6063 RX A700 144 RX V667 HTR 6063 RX A700...