RX-V359/HTR-5930
28
RX-V359/HTR-5930
THM/Fan
(temperature detection/fan drive level)
THM: Temperature detection value
Normal value: 30 to 147 (Reference: 5V=500%)
If THM is out of the normal value range, the
protection function works to turn off the power.
Fan: Current fan drive level on the left and the past fan
drive history on the right.
(Not applied to these models.)
10. AD DATA CHECK/FAN TEST
This menu is used to display the A/D conversion value of
the terminals which detects panel keys of the main unit
and protection functions in % using the sub-menu. During
signal processing, the condition before execution is
maintained.
* The figures in the diagram are given as reference only.
DC/PS
(protection detection)
DC: DC protection value
Normal value: 17 to 29 (Reference: 5V=100%)
If DC is out of the normal value range, the protection
function works to turn off the power.
PS: Power supply voltage protection value
Normal value: 12 to 26 (Reference: 5V=100%)
If PS is out of the normal value range, the protection
function works to turn off the power.
REC-OUT
Not applied to these models.
IMP SW/POWER LIMIT
(Impedance/power limiter detection)
IMP: 8 or 6 ohms impedance switch setting (U, C models)
PL:
Power limiter detection value (Reference: 5.0V=255%)
The voltage value of pin No. 91 of IC242 is displayed.
The port (pin No. 4 of IC242) output is controlled by
using the input voltage.
value of pin No. 91 of IC242.
When higher than VthH, the port output is changed
from H to L.
When lower than VthL, the port output is changed
from L to H.
Note:
Vth=Threshold voltage
[Table 1]
U, C, R, T, K, A, L models
K0/K1
(Panel key of main unit) (Reference: 5V=100%)
A/D of the key fails to function properly when the standard
value is deviated. In this case, check the constant of
partial pressure resistor, solder condition, etc. Refer to
table 1.
FAN DRIVE TEST
(Not applied to these models.)
HIGH
FAN DRIVE TEST
(Not applied to these models.)
LOW
FAN DRIVE TEST
(Not applied to these models.)
MID
When K0/K1 menu is selected, keys become non-
operable due to detection of the values of all keys.
However, it is possible to advance to the next sub-
menu by turning the VOLUME of the main unit. When
using this function, note that turning the VOLUME more
than 2 clicks will cause the volume value to change.
Display (%)
K0
K1
0 - 6
MULTI CH INPUT
TUNING MODE
7 - 13
INPUT SELECT RIGHT
MEMORY
14 - 21
INPUT SELECT LEFT
PRESET / TUNING
22 - 31
INPUT MODE
PRESET / TUNING
32 - 41
PROGRAM
A/B/C/D/E
42 - 53
PROGRAM
FM/AM
54 - 63
BASS /
PRESET / TUNING
64 - 72
BASS / TREBLE -
PTY SEEK MODE
73 - 80
STRAIGHT
PTY SEEK START
81 - 88
TONE CONTROL
EON
89 - 95
SPEAKERS
RDS MODE
96-100
KEY OFF
KEY OFF
B, G, E models
Display (%)
K0
K1
0 - 6
MULTI CH INPUT
TUNING MODE
7 - 13
INPUT SELECT RIGHT
MEMORY
14 - 21
INPUT SELECT LEFT
PRESET / TUNING
22 - 31
INPUT MODE
PRESET / TUNING
32 - 41
PROGRAM
A/B/C/D/E
42 - 53
PROGRAM
FM/AM
54 - 63
BASS /
PRESET / TUNING
64 - 72
BASS / TREBLE -
–
73 - 80
STRAIGHT
–
81 - 88
TONE CONTROL
–
89 - 95
SPEAKERS
–
96-100
KEY OFF
KEY OFF
Detection level
Output level
U, C models (8ohms)
U, C models (6ohms)
R, T, K, A, B, G, E, L models (6ohms)
PORT
No. 91
VthL
2.41V
2.77V
2.77V
VthH
2.90V
3.25V
3.25V
U, C models (8ohms)
U, C models (6ohms)
R, T, K, A, B, G, E, L models (6ohms)
PORT
No. 4
VthL
2.22V
2.0V
2.0V
VthH
4.8V
4.8V
4.8V
Summary of Contents for RX-V359
Page 6: ...RX V359 HTR 5930 6 RX V359 HTR 5930 RX V359 K model RX V359 R model RX V359 T model...
Page 7: ...RX V359 HTR 5930 7 RX V359 HTR 5930 RX V359 B G E models RX V359 A model RX V359 L model...
Page 8: ...RX V359 HTR 5930 8 RX V359 HTR 5930 HTR 5930 T model HTR 5930 U C models HTR 5930 R model...
Page 9: ...RX V359 HTR 5930 9 RX V359 HTR 5930 HTR 5930 A model HTR 5930 K model HTR 5930 B G E models...
Page 44: ...RX V359 HTR 5930 44 RX V359 HTR 5930 MEMO...
Page 72: ...RX V359 HTR 5930 72 RX V359 HTR 5930...
Page 73: ...RX V359 HTR 5930 73 RX V359 HTR 5930...
Page 74: ...RX V359 HTR 5930...