RX-V3200/DSP-AX3200
RX-V3200/DSP-AX3200
435 (17-1/8")
Unit : mm (inch)
191 (7-1/2")
170 (6-11/16")
429 (16-7/8")
21
(13/16")
16
(5/8")
23
(15/16")
468 (18-7/16")
1
WALL
OUTLET
EQUIPMENT
UNDER TEST
AC LEAKAGE
TESTER OR
EQUIVALENT
INSULATING
TABLE
WARNING: CHEMICAL CONTENT NOTICE!
The solder used in the production of this product contains LEAD. In addition, other electrical/electronic and/or plastic (where
applicable) components may also contain traces of chemicals found by the California Health and Welfare Agency (and
possibly other entities) to cause cancer and/or birth defects or other reproductive harm.
DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REA-
SON WHATSOEVER!
Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose
eyes to solder/flux vapor!
If you come in contact with solder or components located inside the enclosure of this product, wash your hands before
handling food.
■
TO SERVICE PERSONNEL
1. Critical Components Information
Components having special characteristics are marked
s
and must be replaced with parts having specifications equal
to those originally installed.
2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.
●
Meter impedance should be equivalent to 1500 ohm shunted
by 0.15
µ
F.
■
IMPEDANCE SELECTOR
IMPEDANCE SELECTOR
WARNING:
Do not change the IMPEDANCE SELECTOR
switch setting while the power to this unit is
on, otherwise this unit may be damaged.
• DIMENSIONS
“CAUTION”
“F311: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 10A, 250V FUSE.”
“F312: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 5A, 125V FUSE.”
CAUTION
F311: REPLACE WITH SAME TYPE 10A, 250V FUSE.
F312: REPLACE WITH SAME TYPE 5A, 125V FUSE.
ATTENTION
F311: UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 10A, 250V.
F312: UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 5A, 125V.
●
Leakage current must not exceed 0.5mA.
●
Be sure to test for leakage with the AC plug in both polarities.