38
RX-Z7/DSP-Z7
RX-Z7/DSP-Z7
Cause:
DC output of the power amplifier is abnormal.
(Normal value: 5 to 34)
Supplementary information:
The abnormal voltage is
displayed in based on 5V as 255.
Turning on the power without correcting the abnormality
will cause the protection function to work 4 seconds later
and the power supply will be shut off.
原因:
パワーアンプの DC 出力が異常。
(正常値:5 〜 34)
補足:
異常時の電圧の状態を、5V を 255 とした値で表示
します。
異常状態のまま電源を入れると、4 秒後にプロテクション
が働き、電源が切れます。
Cause:
The temperature of the heat sink is excessive.
(Normal value: TMP1/TMP2 10 to 83)
Supplementary information:
The abnormal voltage is
displayed in based on 5V as 255.
Turning on the power without correcting the abnormality
will cause the protection function to work 1 second later
and the power supply will be shut off.
*
Additional causes of protection can be due to loose
connections, associated components, Microprocessor,
etc.
*
For the protection voltage value, refer to main menu No.
P1 described later.
原因:
放熱器の温度が異常。
(正常値:TMP1/TMP2 10 〜 83)
補足:
異常時の電圧の状態を、5V を 255 とした値で表示
します。
異常状態のまま電源を入れると、1 秒後にプロテクション
が働き、電源が切れます。
※ 前記の異常原因の他に、コネクターのはずれやマイ
コン周辺などに原因がある場合があります。
※ プロテクションの電圧値に関しては、後述のメイン
メニュー No. P1 を参照してください。
When there is a history of protection function due to abnormal DC output
DC 出力異常によるプロテクション履歴がある場合
A/D conversion value of voltage
電圧の A/D 変換値
A/D conversion value of voltage
電圧の A/D 変換値
When there is a history of protection function due to excessive
heat sink temperature
放熱器の異常温度によるプロテクション履歴がある場合
●
History of protection function
When the protection function has worked, its history
is stored in memory with a backup. Even if no
abnormality is noted while servicing the unit, an
abnormality which has occurred previously can be
defined as long as the backup data has been stored.
The history of the protection function is cleared when
self-diagnostic function is cancelled by selecting
PRESET RESERVED (Memory initialized) of main
menu No. S3 or when the backup data is erased.
● プロテクションの履歴
プロテクションが働いた場合、履歴をバックアップ
して記憶しています。サービスのときに異常が認め
られなくても、バックアップが残っていれば、お客
様のところで起きた異常を区別できます。
プロテクションの履歴は、メインメニュー No. S3 で
PRESET RESERVED(メモリーの初期化)を選んでダ
イアグを解除した場合や、バックアップが消えたと
きにはクリアされます。
Firmware version
ファームウェアバージョン
Firmware version
ファームウェアバージョン
D I A G N O S T I C
D C P R T : 0 0 0 H
D I A G N O S T I C
T M P x P R T : 0 0 0 H
Summary of Contents for RX RX-Z7
Page 4: ...4 RX Z7 DSP Z7 RX Z7 DSP Z7 RX Z7 U C models FRONT PANELS RX Z7 A model U model C model ...
Page 5: ...5 RX Z7 DSP Z7 RX Z7 DSP Z7 DSP Z7 R T K B G E L models DSP Z7 J model ...
Page 6: ...6 RX Z7 DSP Z7 RX Z7 DSP Z7 RX Z7 U model REAR PANELS RX Z7 C model ...
Page 7: ...7 RX Z7 DSP Z7 RX Z7 DSP Z7 RX Z7 A model DSP Z7 R model ...
Page 8: ...8 RX Z7 DSP Z7 RX Z7 DSP Z7 DSP Z7 T model DSP Z7 K model ...
Page 9: ...9 RX Z7 DSP Z7 RX Z7 DSP Z7 DSP Z7 B model DSP Z7 G E models ...
Page 10: ...10 RX Z7 DSP Z7 RX Z7 DSP Z7 DSP Z7 L model DSP Z7 J model ...
Page 148: ...RX Z7 DSP AXZ7 148 MEMO MEMO ...
Page 227: ...RX Z7 DSP Z7 228 ...
Page 228: ...RX Z7 DSP Z7 229 RX Z7 DSP Z7 ...
Page 229: ...RX Z7 DSP Z7 230 RX Z7 DSP Z7 ...
Page 230: ...RX Z7 DSP Z7 231 RX Z7 DSP Z7 ...
Page 231: ...RX Z7 DSP Z7 232 RX Z7 DSP Z7 ...
Page 232: ...RX Z7 DSP Z7 233 RX Z7 DSP Z7 ...
Page 233: ...RX Z7 DSP Z7 234 RX Z7 DSP Z7 ...
Page 234: ...RX Z7 DSP Z7 235 RX Z7 DSP Z7 MEMO ...
Page 235: ...RX Z7 DSP Z7 ...