原因:
パワーアンプに過電流が流れた。
補足:
パワートランジスタの電流を検出していますので、
電流検出トランジスタをチェックすれば異常チャ
ンネルが特定できます。
“MASTER ON/OFF” スイッチを押しても電源が入らなくな
ります。再度電源を入れる場合、一度本機の電源コード
を AC 電源コンセントから抜いて接続し直してください。
When there is a history of protection function:
Cause:
An excessive current flowed through the power
amplifier.
Supplementary information:
As current of the power
transistor is detected, the abnormal channel can be
identified by checking the current detect transistor.
The power will not turn on even when the “MASTER ON/
OFF” switch is pressed. To turn on the power again,
disconnect the power cable to this unit from the AC outlet
and then reconnect it again.
After a few seconds /
数秒後
After a few seconds /
数秒後
Main menu display /
メインメニュー表示
Opening message /
オープニング表示
When there is no protection history
プロテクション履歴が無い場合
過電流によるプロテクション履歴がある場合
When there is a history of protection function due to
excess current
When there is a history of protection function due to excess current
過電流によるプロテクション履歴がある場合
プロテクション履歴がある場合 :
Firmware version
ファームウェアバージョン
Firmware version
ファームウェアバージョン
● ダイアグの解除
① ダイアグを解除する前に、メインメニュー No. S3 の
FACTORY PRESET(メモリーの初期化禁止 / またはメ
モリーの初期化)の設定をします。
※ ユ ー ザ ー メ モ リ ー を 保 持 し た い 場 合 は、 必 ず
PRESET INHIBIT(メモリー初期化禁止)を選択し
てください。
② 本機の “MASTER ON/OFF” スイッチを押して電源を
切ります。
● ダイアグ起動時の表示
本機の FL ディスプレイにモデル名が表示されます。その
後、数秒間隔でプロテクション履歴情報とバージョン(英
1 文字)、メインメニュー(No. A1 DSP THROUGH のサブ
メニュー MARGIN)が表示されます。
プロテクション履歴がない場合 :
●
Canceling Self-Diagnostic Function
➀
Before canceling self-diagnostic function, execute
setting for PRESET of main menu No. S3 (Memory ini-
tialization inhibited or Memory initialized).
* In order to keep the user memory stored, be sure
to select PRESET INHIBIT (Memory initialization
inhibited).
➁
Press the “MASTER ON/OFF” switch of this unit to
turn off the power.
●
Display provided when Self-Diagnos-
tic Function started
The FL display of this unit displays the model name, fol-
lowed by the protection function history data, the version
(1 alphabet) and the main menu (sub-menu MARGIN of
main menu No. A1 DSP THROUGH) at a few seconds in-
tervals.
When there is no history of protection function:
D I A G N O S T I C
N O P R O T E C T H
D I A G N O S T I C
D S P - Z 7
A 1 . D S P T H R O U G H
M A R G I N
D I A G N O S T I C
I P R O T E C T H
Summary of Contents for RX RX-Z7
Page 4: ...4 RX Z7 DSP Z7 RX Z7 DSP Z7 RX Z7 U C models FRONT PANELS RX Z7 A model U model C model ...
Page 5: ...5 RX Z7 DSP Z7 RX Z7 DSP Z7 DSP Z7 R T K B G E L models DSP Z7 J model ...
Page 6: ...6 RX Z7 DSP Z7 RX Z7 DSP Z7 RX Z7 U model REAR PANELS RX Z7 C model ...
Page 7: ...7 RX Z7 DSP Z7 RX Z7 DSP Z7 RX Z7 A model DSP Z7 R model ...
Page 8: ...8 RX Z7 DSP Z7 RX Z7 DSP Z7 DSP Z7 T model DSP Z7 K model ...
Page 9: ...9 RX Z7 DSP Z7 RX Z7 DSP Z7 DSP Z7 B model DSP Z7 G E models ...
Page 10: ...10 RX Z7 DSP Z7 RX Z7 DSP Z7 DSP Z7 L model DSP Z7 J model ...
Page 148: ...RX Z7 DSP AXZ7 148 MEMO MEMO ...
Page 227: ...RX Z7 DSP Z7 228 ...
Page 228: ...RX Z7 DSP Z7 229 RX Z7 DSP Z7 ...
Page 229: ...RX Z7 DSP Z7 230 RX Z7 DSP Z7 ...
Page 230: ...RX Z7 DSP Z7 231 RX Z7 DSP Z7 ...
Page 231: ...RX Z7 DSP Z7 232 RX Z7 DSP Z7 ...
Page 232: ...RX Z7 DSP Z7 233 RX Z7 DSP Z7 ...
Page 233: ...RX Z7 DSP Z7 234 RX Z7 DSP Z7 ...
Page 234: ...RX Z7 DSP Z7 235 RX Z7 DSP Z7 MEMO ...
Page 235: ...RX Z7 DSP Z7 ...