14
RX-497
RX-497
5. PROTECTION SETTING
This menu is used to change the protection setting value.
The change is effective in this menu only. A set value can
be specified between 0 – 255 (0V – 5V).
Operation:
Change the digit with the “EDIT” key.
UP / DOWN with the TUNING MODE / MEMORY key.
PS_Lo:
0138
PS_Hi:
0215
DC_Lo:
0049
DC_Hi:
0131
TEMP
:
0089
The PS protection LO level threshold value can be set.
Protection operates when the voltage value of the de-
tection terminal falls below this value.
The PS protection HI level threshold value can be set.
Protection operates when the voltage value of the de-
tection terminal exceeds this value.
The DC protection LO level threshold value can be set.
Protection operates when the voltage value of the de-
tection terminal falls below this value.
The DC protection HI level threshold value can be set.
Protection operates when the voltage value of the de-
tection terminal exceeds this value.
The TEMP protection HI level threshold value can be
set.
Protection operates when the voltage value of the de-
tection terminal exceeds this value.
6. PROTECTION HISTORY
Four protection histories are display.
The history is cleared by the initialization reservation of DIAG
menu No. 2.
When there is no history of protection function:
There is no history of protection function.
6-1
NoPRT
When there is a history of protection function:
There is a history of protection function due to excess cur-
rent.
6-1
I
PRT
There is a history of protection function due to abnormal
voltage in the power supply section.
The abnormal voltage is displayed in % based on 5V as
100%.
6-2
PsPRT
069
There is a history of protection function due to abnormal
DC output.
The abnormal voltage is displayed in % based on 5V as
100%.
6-3
DcPRT
059
There is a history of protection function excessive heatsink
temperature. (R ch)
The abnormal voltage is displayed in % based on 5V as
500%.
6-4
TmRPRT
245
There is a history of protection function excessive heatsink
temperature. (L ch)
Not applied to this model.
6-4
TmLPRT
245
* The numeric value in the diagram is for reference.