52
RM1x
(3-4) SYSTEM REAL TIME MESSAGE
Not recorded as Sequence Data.
(3-4-1) TIMING CLOCK
STATUS
11111000(F8H)
You can select whether the internal clock will be used as the Timing Clock, or whether Timing Clock
messages from the MIDI IN will be used.
Transmission/reception can be turned On/Off.
(3-4-2) START
STATUS
11111010(FAH)
Transmission/Reception can be turned On/Off.
(3-4-3) CONTINUE
STATUS
11111011(FBH)
Transmission/Reception can be turned On/Off.
(3-4-4) STOP
STATUS
11111100(FCH)
Transmission/Reception can be turned On/Off.
(3-5) SYSTEM EXCLUSIVE MESSAGE
All System Exclusive Messages are recorded and played back.
Even if time intervals existed within the actual data that was received, the entire message between F0
and F7 will be recorded into one timing location.
For playback, an interval time can be specified for each 1K bytes.
(3-6) SECTION CONTROL
11110000
F0
Exclusive status
01000011
43
YAMAHA ID
01111110
7E
Style
00000000
00
Section Control
0sssssss
ss
Section
0ddddddd
dd
On/Off
11110111
F7
End of Exclusive
ss=08H-0FH, dd=on is received, and the PATTERN will be changed to the RM1x's sections A - P
respectively.
<Table 1-1> Parmeter Base Address
Parameter Change
Address
(H)
(M)
(L)
Description
SYSTEM
00
00
00
System
00
00
7E
XG System On
00
00
7F
All Parameter Reset
INFORMATION
01
00
00
System Information
EFFECT 1
02
01
00
Effect1(Reverb,Chorus,Variation )
02
40
00
Reserved
:
:
:
:
MULTI PART
08
00
00
Multi Part 1
:
08
0F
00
Multi Part 16
08
10
00
Reserved
:
:
:
:
<Table 1-2> MIDI Parameter Change table ( SYSTEM )
Address
Size
Data
Parameter Name
Description
Default
(H)
(H)
(H)
value(H)
00 00 00
4
0000
Master Tune
-102.4..+102.3[cent]
00 04 00 00
01
..07FF
1st bit3-0
→
bit15-12
(0400)
02
2nd bit3-0
→
bit11-8
(not reset by XG or GM on)
03
3rd bit3-0
→
bit7-4
(not reset by XG or GM on)
4th bit3-0
→
bit3-0
04
1
00..7F
Master Volume
0..127
7F
05
1
Not Used
06
1
28..58
Transpose
-24..+24[semitones]
40
7D
Not Used
7E
00
XG System On
00=XG Sytem on (receive only)
7F
00
All Parameter Reset
00=on (receive only)
TOTAL SIZE 06
<Table 1-3> MIDI Parameter Change table ( EFFECT 1)
Address
Size
Data
Parameter Name
Description
Default
(H)
(H)
(H)
value(H)
02 01 00
2
00..7F
Reverb Type MSB
Refer to Ef. Parameter List
01(=HALL1)
00..7F
Reverb Type LSB
00 : basic type
00
02
1
00..7F
Reverb Parameter 1
Refer to Ef. Parameter List
depends on Reverb type
03
1
00..7F
Reverb Parameter 2
Refer to Ef. Parameter List
depends on Reverb type
04
1
00..7F
Reverb Parameter 3
Refer to Ef. Parameter List
depends on Reverb type
05
1
00..7F
Reverb Parameter 4
Refer to Ef. Parameter List
depends on Reverb type
06
1
00..7F
Reverb Parameter 5
Refer to Ef. Parameter List
depends on Reverb type
07
1
00..7F
Reverb Parameter 6
Refer to Ef. Parameter List
depends on Reverb type
08
1
00..7F
Reverb Parameter 7
Refer to Ef. Parameter List
depends on Reverb type
09
1
00..7F
Reverb Parameter 8
Refer to Ef. Parameter List
depends on Reverb type
0A
1
00..7F
Reverb Parameter 9
Refer to Ef. Parameter List
depends on Reverb type
0B
1
00..7F
Reverb Parameter 10
Refer to Ef. Parameter List
depends on Reverb type
0C
1
00..7F
Reverb Return
-°..0..+6dB(0..96..127)
40
0D
1
01..7F
Reverb Pan
L63..C..R63(1..64..127)
40
TOTAL SIZE 0E
(3-7) MIDI TIME CODE(QUARTER FRAME MESSAGE)
STATUS
11110001(F1H)
0nnnxxxx
If MTC is selected as the Timing Clock, MTC Quarter Frame messages will be received.
(3-8) MIDI MACHINE CONTROL
These will be transmitted if MTC is selected as the Timing Clock.
(3-8-1) STOP(MCS)
11110000
F0
Exclusive status
01111111
7F
RealTime Header
01111111
7F
device ID
00000110
06
MMC Command Message
00000001
01
STOP(MCS)
11110111
F7
End of Exclusive
Transmitted when the STOP button is pressed.
(3-8-2) DEFERRED PLAY(MCS)
11110000
F0
Exclusive status
01111111
7F
RealTime Header
01111111
7F
device ID
00000110
06
MMC Command Message
00000011
03
DEFERRED PLAY(MCS)
11110111
F7
End of Exclusive
Transmitted when the PLAY button is pressed.
(3-8-3) LOCATE(MCP)
11110000
F0
Exclusive status
01111111
7F
RealTime Header
01111111
7F
device ID
00000110
06
MMC Command Message
01000100
44
LOCATE(MCP)
00000110
06
Byte Count
00000001
01
"TERGET" Sub Command
0tthhhhh
hr
standard time specification with sub-frames
0cmmmmmm
mn
0kssssss
sc
0gifffff
fr
0bbbbbbb
ff
11110111
F7
End of Exclusive
Transmitted when you move between measures in the SONG mode.