4-280
Chapter
4
OPERA
TION
4-281
14. "UTILITY" mode
14.3 Enabling/disabling the sequence execution flag
To enable or disable execution of sequence programs, proceed as follows.
n
NOTE
The following conditions must be satisfied before executing a sequence
program.
1. An object program must be made for sequence execution.
2. Sequence execution must be enabled.
3. DI10 (Sequence permit) contact point must be closed.
4. Operation must be in "AUTO" mode or "MANUAL" mode.
[Procedure]
1) Press
(SEQUENC) in "UTILITY" mode.
2) To enable execution of sequence programs, press
(ENABLE).
To disable execution of sequence programs, press
(DISABLE).
To enable DO reset during sequence program execution, press
(RST.DO).
■
Enabling/disabling the sequence program
UTILITY
>SEQUENC
Scan time : 10msec
Sequence : ENABLE
ENABLE
DISABLE
Summary of Contents for RCX222