![Yamaha Raptor YFM350S Service Manual Download Page 46](http://html.mh-extra.com/html/yamaha/raptor-yfm350s/raptor-yfm350s_service-manual_895392046.webp)
– 38 –
CHK
ADJ
CHECKING AND CHARGING THE BATTERY
Charging method using a variable-current (voltage) charger
Measure the open-circuit
voltage prior to charging.
Connect a charger and
ammeter to the battery and
start charging.
Is the amperage higher
than the standard charging
amperage written on the
battery?
Adjust the charging voltage to
20 ~ 25 V.
Adjust the voltage to obtain the
standard charging amperage.
Monitor the amperage for
3 ~ 5 minutes. Is the standard
charging amperage exceeded?
Set the timer to the charging
time determined by the open-
circuit voltage.
Refer to “CHECKING AND
CHARGING THE BATTERY”.
If the amperage does not
exceed the standard charging
amperage after 5 minutes,
replace the battery.
If the required charging time exceeds 5 hours, it is advisable to check the
charging amperage after 5 hours. If there is any change in the amperage,
readjust the voltage to obtain the standard charging amperage.
Leave the battery unused for more than 30 minutes before measuring its
open-circuit voltage.
12.8 V
→
Charging is complete.
12.0 ~ 12.7 V
→
Recharging is required.
Under 12.0 V
→
Replace the battery.
NOTE:
Leave the battery unused for
more than 30 minutes before
measuring its open-circuit voltage.
NOTE:
Set the charging voltage to 16 ~
17 V. (If the charging voltage is
lower, charging will be insufficient,
if it is higher, the battery will be
over-charged.)
NO
YES
NO
YES
Charger
Ammeter
Summary of Contents for Raptor YFM350S
Page 1: ...YFM350S3GD AE7 SUPPLEMENTARY SERVICE MANUAL ...
Page 2: ......
Page 66: ......
Page 67: ......
Page 68: ...YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN ...