42
Appendix
2.1.4.2 PLG100-DX Part Parameter Change
This message sets the PLG100-DX MULTI PART block (see Tables <2-1> and
<2-3>).
2.1.5 DX Parameter Change
11110000
F0H
Exclusive status
01000011
43H
YAMAHA ID
0001nnnn
1NH
N:Device Number
0ggggghh
GGH
Parameter Group No.
0ppppppp
PPH
Parameter No.
0vvvvvvv
VVH
Data
11110111
F7H
End of Exclusive
2.1.5.1 VCED parameter change
This message sets the VCED block (see Tables <3-1> and <3-2>).
2.1.5.2 ACED parameter change
This message sets the ACED block (see Tables <3-1> and <3-3>).
2.2 Bulk dump
This device uses only the following bulk dump messages.
[XG BULK DUMP]
1) XG System bulk dump
2) Multi Part bulk dump
[PLG100-DX NATIVE BULK DUMP]
1) System bulk dump
2) Part bulk dump
[DX BULK DUMP]
1) VCED
2) ACED
3) VMEM
4) AMEM
2.2.1 XG bulk dump
This message sets XG-related parameters. Unlike parameter change messages,
a single message can modify multiple parameters. The message format is as
follows.
11110000
F0H
Exclusive status
01000011
43H
YAMAHA ID
0000nnnn
0NH
N:Device Number
01001100
4CH
Model ID
0sssssss
SSH
ByteCountMSB
0ttttttt
TTH
ByteCountLSB
0ggggggg
GGH
Address High
0mmmmmmm
MMH
Address Mid
0lllllll
LLH
Address Low
0vvvvvvv
VVH
Data
:
:
0kkkkkkk
KKH
Check-sum
11110111
F7H
End of Exclusive
Address and Byte Count are given in tables <1-n>. Byte Count is indicated by
the total size of the Data in tables <1-n>.
Bulk dump is received when the beginning of the block is specified in “Ad-
dress”.
‘Block’ indicates the unit of the data string that is indicated in tables 1-n as
‘Total size’.
Check sum is the value that produces a lower 7 bits of 0 when the Start Address,
Byte Count, Data, and the Check sum itself are added.
2.2.1.1 XG System bulk dump
This message sets the XG SYSTEM block (see Tables <1-1>, <1-2>).
2.2.1.2 Multi Part bulk dump
This message sets the MULTIPART block (see Tables <1-1>, <1-3>).
2.2.2 PLG100-DX Native Bulk Dump
This message sets the special parameters for PLG100-DX. Unlike Parameter
change, one message can modify multiple parameters.
11110000
F0H
Exclusive status
01000011
43H
YAMAHA ID
0000nnnn
0NH
N:Device Number
01100010
62H
Model ID
0sssssss
SSH
ByteCountMSB
0ttttttt
TTH
ByteCountLSB
0ggggggg
GGH
Address High
0mmmmmmm
MMH
Address Mid
0lllllll
LLH
Address Low
0vvvvvvv
VVH
Data
:
:
0kkkkkkk
KKH
Check-sum
11110111
F7H
End of Exclusive
The details are the same as for 2.2.1 XG Bulk Dump. However, see Tables <2-
n> for the Address, Byte Count, and block.
2.2.2.1 PLG100-DX System Bulk Dump
This message sets the PLG100-DX SYSTEM block (see Tables <2-1>, <2-2>).
2.2.2.2 PLG100-DX Multi Part bulk dump
This message sets the PLG100-DX MULTI PART block (see Tables <2-1>, <2-
3>).
2.2.3 DX bulk dump
11110000
F0H
Exclusive status
01000011
43H
YAMAHA ID
0000nnnn
0NH
N:Device Number
0ttttttt
TTH
Format No.
0sssssss
SSH
ByteCountMSB
0ttttttt
TTH
ByteCountLSB
0vvvvvvv
VVH
Data
:
:
0kkkkkkk
KKH
Check-sum
11110111
F7H
End of Exclusive
Address and Byte Count are given in tables <3-n>. Byte Count is indicated by
the total size of the Data in tables <4-n>.
Bulk dump is received when the beginning of the block is specified in “Ad-
dress”.
“Block” indicates the unit of the data string that is indicated in tables 3-n as
“Total size”.
Check sum is the value that produces a lower 7 bits of 0 when the DATA, and
the Check-sum itself are added.
2.2.3.1 VCED Bulk Dump
This message sets the VCED block (see Tables <4-1> and <3-2>.
2.2.3.2 ACED Bulk Dump
This message sets the ACED block (see Tables <4-1> and <3-3>.
2.2.3.3 VMEM Bulk Dump
This message sets the VMEM block (see Tables <4-1> and <4-2>.
2.2.3.4 AMEM Bulk Dump
This message sets the AMEM block (see Tables <4-1> and <4-3>.
3. Realtime Messages
3.1 Active Sensing
a) Send
Do not send.
b) Receive
After FE is received one time, if the MIDI signal does not come within 400
msec, PLG100-DX will act the same as when ALL SOUND OFF, ALL NOTE
OFF, and RESET ALL CONTROLLERS are received, and return to the condi-
tion where FE has not been received once.
<1-1>
Parameter Base Address
MODEL ID = 4C
Parameter
Address
Description
(H)
(M)
(L)
XG SYSTEM
00
00
00
System
00
00
7E
XG System On
00
00
7F
All Parameter Reset
MULTI PART
08
00
00
Multi Part 1
:
08
0F
00
Multi Part 16
MULTI PART
0A
00
00
Multi Part 1
(additional)
:
:
0A
0F
00
Multi Part 16
PART ASSIGN
70
02
00
PLG100-DX Part Assign