6/13
M7CL Quick Start Guide Part 3
To apply Recall Safes.
The RECALL SAFE MODE pop-up is in the CH JOB (Channel Job) area. Press the [CH JOB] button on the screen and
then press the [RECALL SAFE] button, the pop-up will appear.
Recall Safes can be applied from this screen and the safe
parameters can be selected.
To apply a safe, select the channel to display its setting in
the lower part of the pop-up. Select the parameters to be
safed (eg [ALL] or [HA] and [EQ]). Turn on the safe with
the [SAFE] button. This setting can be applied to many
channels quickly by using the [SET BY SEL] button in the
box above.
Channels with all parameters safed are shown green.
Channels with partial safes are shown blue. There are
many possible partial safe combinations but all are shown
in blue.
It is easy to create mute scenes by selecting all the buttons other than [CH ON] from the SAFE PARAMETER SELECT
part of the RECALL SAFE MODE pop-up and applying this to all channels. In this case each scene will operate the
channel ON/OFF parameter. Check to safe all the [RACK], [NAME] and [PATCH] boxes too.
Turning safes on and off.
Safes can be turned on and off from the SELECTED
CHANNEL VIEW and there is also a short-cut to the
RECALL SAFE MODE pop-up. If the safe is set to a
partial setting this will be indicated here and the partial
setting remains even when switched off.