8-46
–
+
ELEC
E
CHECKING THE EMERGENCY
SWITCH
8
1. Check:
• Emergency switch continuity
Out of specification
→
Replace.
2. Check:
• Emergency switch
Does not automatically return to the
home position
→
Replace.
Switch
position
Lead color
Blue (L) – Black (B)
Home
a
No
continuity
On
b
Continuity
8710
CHECKING THE OIL PUMP
(SUB-OIL TANK)
8
Check:
• Oil pump (sub-oil tank)
Incorrect operation
→
Replace.
NOTE:
Connect the oil pump leads to a 12-V bat-
tery and make sure the oil pump operates
properly.
Blue (L) lead
→
Positive battery terminal
Brown (Br) lead
→
Negative battery terminal
8720
OIL FEED PUMP CONTROL SYSTEM