KX-E300
KX-E300
10
“MECHANICAL ADJUSTMENT”
Item to be
Adjusted
Check each
torque
Check FF, REW
take up time
Azimuth
Tape Speed
Wow/Flutter
Tape
CT-160L (FF, REW)
TW-2111A (FWD)
TW-2121A (RVS)
AC-514 (C-60)
MTT-114N
10kHz, –10dB
MTT-111N
3kHz, –10dB
MTT-111N
3kHz, –10dB
Step
1
2
3
4
5
Mode
FF REW
PLAY
FF REW
PLAY
PLAY
PLAY
Rating
FF, REW torque : within 70—150g/cm.
Take up torque : 30—70g/cm.
Back tension : 1.5—6g/cm.
80 to 120 seconds.
Playback output of L and R is maxi-
mum and phase difference should
be minimum both directions. (Fig. B)
*3000 Hz
Less than 0.19% (WRMS)
Remarks
After the adjustment
make sure to apply
screw lock paint.
Take measurement at
about the center of the
test tape. Perform ad-
justment in the forward
direction and check the
tape speed in the re-
verse direction.
Take measurement at
about the center of the
test tape.
Instrument
required
Torque
meter
ACVM
Oscilloscope
Frequency
counter
Wow/flutter
meter
Adjustment
part
Azimuth
adjustment
screw. (Fig. B)
VR101
メカ調整
調整項目
各トルクの確認
FF 、REW 時
間の確認
アジマス
テープスピード
ワウ・フラッター
の確認
テストテープ
CT-160L (FF, REW)
TW-2111A (FWD)
TW-2121A (RVS)
AC-514 (C-60)
MTT-114N
10kHz, −10dB
MTT-111N
3kHz, −10dB
MTT-111N
3kHz, −10dB
Step
1
2
3
4
5
モード
FF REW
PLAY
FF REW
PLAY
PLAY
PLAY
調整方法&規格
FF 、REW トルク:70 〜 150g/cm
テイクアップ:30 〜 70g/cm
バックテンション:1.5 〜6g/cm
80 〜 120 秒
再生レベルが最大で左右の位相
差が最小となるように調整す
る。(Fig.B )
*3000 Hz
0.19%(WRMS )以下
備考
調 整 後 、 必 ず ネ ジ
ロックを施すこと。
テストテープの中央
付近で測定すること。
フォワード方向で調整し、
リバース方向でテープス
ピードを確認すること。
テストテープの中央
付近で測定すること。
測定器
トルクメー
ター
ACVM
オシロスコープ
周波数
カウンター
ワウ・フラッ
ターメーター
調整箇所
アジマス
調整ネジ
(Fig.B )
VR101
+ 30
- 15
+ 30
- 15
* モーターまたはカセットメカ交換後は、モーターの初期特性を補うために 2980 Hz に設定します。
+ 30
- 15
* After replacing the motor or cassette mechanism, perform adjustment in the rating of 2980 Hz to compensate the motor’s initial
characteristic.
+ 30
- 15