background image

CAUTIONS

2

٨
٨
٨
٨
٨

٨

٨

٨

٨

٨
٨

٨
٨

٨

٨

This product has been developed / produced for industrial use only.
Make sure that the power supply is off while wiring.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator, ensure that the frame 
ground (F.G.) terminal of the power supply is connected to an actual ground.
In case noise generating equipment (switching regulator, inverter motor, etc.) is 
used in the vicinity of this product, connect the frame ground (F.G.) terminal of the 
equipment to an actual ground.
Do not run the wires together with high-voltage lines or power lines or put them in 
the same raceway. This can cause malfunction due to induction.
Take care that the sensor is not directly exposed to fluorescent lamp from a rapid-
starter lamp, a high frequency lighting device or sunlight etc., as it may affect the 
sensing performance.
Do not use during the initial transient time (200ms) after the power supply is 
switched on.
The cable length should be up to 100m.
When connecting the induction load for a load, 
such as DC relay, the measure against surge 
should be done, as shown in the figure right.
This sensor is suitable for indoor use only.
Do not use this sensor in places having excessive vapor, dust, etc., or where it 
may come in contact with water, or corrosive gas.
Take care that the sensor does not come in contact with water, oil, grease, organ-
ic solvents, such as, thinner etc., or strong acid, and alkaline.
The following items are required, as conditions for use in order to conform to CE Marking.

The output applied voltage should be the same as the supply voltage of the sensor. 

Be sure to add a short-circuit protection (a fuse or a breaker) to the power sup-
ply input and the output.

DC
power

Sensor
output

+

-

DC relay

MOUNTING THE SHORT-CIRCUIT METAL 

JOINT (VF-SKG)

6

٨

If the sensor and the load are supplied power from the same power supply, the 
number of wires can be reduced by one by using the enclosed short-circuit metal 
joint.

Loosen the screws on terminals 

ԙ

 and 

Ԛ

.

Mount the short-circuit metal joint 

VF-SKG

 on the 

terminals as shown on the right.

How to mount

Short-circuit 
metal joint

Connection example

Power supply

Load

Short-circuited by the short-
circuit metal joint (

VF-SKG

)

Terminal No.

Multi-
voltage 
circuit

Output relay

Main circuit

WIRING

5

٨

Prepare the cable end as shown below.
To maintain a watertight performance, the cable should have an outer diameter 
between 

Ǿ

6 to 

Ǿ

10mm with a smooth covering material that allows the gland to 

be securely tightened, however, the tightening torque of the screw should be of 
0.96 to 1.44N

m.

٨

٨

٨

Check the terminal No. first and 
connect from the terminal No. 

Ԙ

.

However, the tightening torque of 
the screw should be of 0.48N

m or 

less.
Fix the cover with the mounting 
screw.
However, the tightening torque of the screw should be of 0.48 to 0.76N

m.

Dimensions of the suitable crimp terminals

Cable

Gland

Gland washer

Gland packing (2 Nos. enclosed)

Outer dia: 

Ǿ

6 to 

Ǿ

10mm

Conductor cross section area:
0.25 to 0.75mm

2

Small hole: For 

Ǿ

6 to 

Ǿ

8mm cable

Large hole: For 

Ǿ

8 to 

Ǿ

10mm cable

80mm

Output

Power
supply

65mm

}

}

Terminal No.

}

}

Power

supply

Output

Note:  Use crimp terminals with insulating sleeves.

Recommended crimp terminal: Nominal size 1.25

˜

3.5

(After crimping)

7
or less

7
or less

10 or less

19 or less

Ǿ

3.6 or more

(After crimping)

7
or less

7
or less

10 or less

19 or less

Ǿ

3.6 or more

Round type

Y-shaped type

(Unit: mm)

MOUNTING

3

٨

The tightening torque should be 
0.78N

m or less.

Sensor mounting bracket

MS-N70

(Accessory)

I/O CIRCUIT DIAGRAMS

4

Note: The emitter of the thru-beam type sensor 

has only two terminals for power supply 
(terminal No. 

Ԙ

 and 

ԙ

).

Terminal No.

Multi-
voltage 
circuit

Output relay

Main circuit

Relay contact
(1a)

Internal circuit

Power supply
24 to 240V AC

%

or

12 to 240V DC

%

+10

-15

+10

-15

SPECIFICATIONS

1

Notes: 1) 

2) 

3) 

4) 

The model No. with suffix '

T

' stands for the timer incorporated models.

The model No. with suffix '

P

' shown on the label affixed to the thru-beam type sensor is 

the emitter, '

D

' shown on the label is the receiver.

(e.g.) Thru-beam type sensor emitter: 

VF-M10P

, Thru-beam type sensor receiver: 

VF-M10D

The retroreflective type sensor with polarizing filters may not stably detect specular or 
glossy objects through transparent film since light is polarized by the transparent film. For 
details, refer to '    

RETROREFLECTIVE TYPE SENSOR WITH POLARIZING FILTERS

'.

The sensing range for the retroreflective type sensor are specified for the 

RF-230

 reflector. 

Further, the sensing range is the possible setting range for the reflector. The sensor can 
detect an object less than 0.1m (

VF-PRM3

: 0.2m) away.

The sensing range of the diffuse reflective type sensor is specified for white non-glossy 
paper (200

˜

200mm) as the object.

9

Emitter: 3VA or less

Average:
1.5W or less

Receiver: 3VA or less

Average:
1.5W or less

MS-N70

 (Sensor mounting bracket): 1 set, Gland and gland washer: 1 set

Gland packing (large / small 1 pc. each): 1 set, 

VF-SKG

 (Short-circuit metal joint): 1 pc.

RF-230

 (Reflector): 1 pc. for the retroreflective type sensor

Adjusting screwdriver: 1 pc. for the diffuse reflective type sensor and for sensors with timer functions

2 sets of sensor mounting bracket, gland, gland washer and gland 
packing are attached for the thru-beam type sensors.

IP66 (IEC)

Protection

15% or less of operation distance

Hysteresis

10m

0.1 to 5m

(Note 3)

1m

(Note 4)

500mm

(Note 4)

0.2 to 3m

(Note 3)

VF-M10

(

T

)

VF-RM5

T

VF-PRM3

VF-D500

(

T

)

VF-D1000

(

T

)

Thru-beam

Diffuse reflective

With polarizing 
filters (Note 2)

Retroreflective

Sensing range

Type

Item

Model No. (Note 1)

Supply voltage

Relay contact 1a

Switching capacity: 250V 1A AC (resistive load)

30V 2A DC (resistive load)

Electrical life: 500,000 or more switching operations

(switching frequency 3,600 operations/hour)

Mechanical life: 100,000,000 or more switching operations

(switching frequency 36,000 operations/hour)

3VA or less

(Average: 1.5W or less)

Power / Current 
consumption

Output

Response time

Emitter:

75g approx.

Receiver:

95g approx.

Accessories

95g approx.

Weight

Enclosure: PBT
Lens: Acrylic (front surface of retroreflective type sensor with polarizing filters: Triacetate)

Material

35 to 85% RH, Storage: 35 to 85% RH

Ambient humidity

-10 to +60

͠

 (No dew condensation or icing allowed), Storage: -20 to +70

͠

Ambient temperature

20ms or less

24 to 240V AC

% or 12 to 240V DC

%

+10

-15

+10

-15

٨
٨

Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products which 
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protec-
tion applicable in each region or country.

WARNING

Thank you very much for purchasing Panasonic products. Please read this Instruction 
Manual carefully and thoroughly for the correct and optimum use of this product. 
Kindly keep this manual in a convenient place for quick reference.

INSTRUCTION MANUAL

Multi-voltage Terminal Connection Type Photoelectric Sensor

VF

 Series

Reviews: