RX-V363/HTR-6130
24
RX-V363/HTR-6130
Cause:
The temperature of the heat sink is excessive.
Supplementary information:
The protection function worked due to the temperature limit being exceeded.
Causes could be poor ventilation or a defect related to the thermal sensor.
History of protection function
When the protection function has worked, its history is stored in memory with a backup.
Even if no abnormality is noted while servicing the unit, an abnormality which has occurred previously can be
defined as long as the backup data has been stored.
The history of the protection function is cleared when self-diagnostic function is cancelled by selecting PRESET
RESERVED (Memory initialized) of main menu No. 13 or when the backup data is erased.
When there is a history of protection function due to abnormal voltage in the power supply section
Cause:
The voltage in the power supply section is abnormal.
Supplementary information:
The protection function worked due to a defect or overload in the power supply.
If the power is turned on with the abnormality unsolved, the protection function works in about 1 second to turn
off the power.
PRV
PRT:xxx
AD value when the protection function is working
THM
PRT:xxx
AD value when the protection function is working
When there is a history of protection function due to excessive heat sink temperature
If the power is turned on with the abnormality unsolved, the protection function works in about 1 second to turn off the power.
For detection of each protection function, refer to main menu described later.
Summary of Contents for HTR-6130
Page 3: ......
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 98: ...99 RX V363 HTR 6130 RX V363 HTR 6130 ...
Page 99: ...RX V363 HTR 6130 本资料由OKXIA视听皮带资源库www okxia cn提供 ...