Instrument an
d
control functions
3-41
3
Compression
d
ampin
g
force
The compression damping force is ad-
justed on the right front fork leg only.
To increase the compression damping
force and thereby harden the com-
pression damping, turn the adjusting
screw in direction (a). To decrease the
compression damping force and there-
by soften the compression damping,
turn the adjusting screw in direction (b).
TIP
Although the total number of clicks of a
damping force adjusting mechanism
may not exactly match the above
specifications due to small differences
in production, the actual number of
clicks always represents the entire ad-
justing range. To obtain a precise ad-
justment, it would be advisable to
check the number of clicks of each
damping force adjusting mechanism
and to modify the specifications as
necessary.
Re
b
oun
d
d
ampin
g
settin
g
:
Minimum (soft):
22 click(s) in direction (b)*
Standard:
12 click(s) in direction (b)*
Maximum (hard):
1 click(s) in direction (b)*
* With the adjusting knob fully turned
in direction (a)
1. Compression damping force adjusting
screw
Compression
d
ampin
g
settin
g
:
Minimum (soft):
32 click(s) in direction (b)*
Standard:
11 click(s) in direction (b)*
Maximum (hard):
1 click(s) in direction (b)*
* With the adjusting screw fully
turned in direction (a)
UB88E0E0.book Page 41 Friday, October 16, 2015 11:59 AM