background image

Controls and Connectors

EXi

8

/EXo

8

 O

w

ner’s Man

u

al

8

q

Ground screw

The supplied power cord has a three-prong plug that will 
ground the device when plugged into an appropriately 
grounded three-prong type AC mains outlet. In some cases, 
you may be able to reduce hum or interference by also con-
necting this screw to ground.

w

AC IN connector

Use the included power cord to supply power to this connec-
tor. First, connect the power cord to this device, and then 
insert the power cord plug into the AC outlet.

e

[UNIT ID] rotary switch

This switch specifies the ID by which EXi8/EXo8 units are 
individually distinguished in the MTX system network. You 
must specify the ID avoiding duplicates among the MTX 
series, XMV series and the EXi8/EXo8 within the same net-
work.
DIP switches 1 and 2 described in 

r

 specify the upper digit, 

and this rotary switch specifies the lower digit, together 
allowing you to set the UNIT ID to one of 63 possibilities in 
the range of 01 to 3F.

r

DIP switches

These switches enable you to specify the settings related to 
the startup operation of the EXi8/EXo8.

Refer to the following for details.

Switches 1–2 (UNIT ID)

These switches specify the upper digit and the above-
mentioned [UNIT ID] rotary switch specifies the lower 
digit, together allowing you to specify one of 63 different 
UNIT ID numbers in a range from 01 to 3F.

Switch 3

This switch is for future expansion. Set this to its upward 
position.

Switches 4–5 (REMOTE)

Settings of these switches are not necessary. Set these to 
their upward position.

Rear Panel

ON

q

w

e r

y

u

t

i

* Illustration shows EXi8.

NOTE

The EXi

8

/EXo

8

 has some connectors that are shaped identically 

bu

t ha

v

e a completely different f

u

nction (e.g., NETWORK connec-

tor, [YDIF] connector). Make the appropriate connections as 
instr

u

cted 

b

y the explanation for each connector. Other

w

ise, yo

u

 

risk damaging yo

u

r eq

u

ipment.

NOTE

• Do not 

u

se a UNIT ID of “00” (DIP s

w

itches 1 and 2 

u

p

w

ard and the rotary s

w

itch at 0).

• Yo

u

’ll need to restart the de

v

ice after changing the setting 

of the [UNIT ID] rotary s

w

itch.

NOTE

Set the DIP s

w

itches 

w

hile the po

w

er to the 

u

nit is t

u

rned 

OFF. Other

w

ise, the setting 

w

ill not 

b

e effecti

v

e.

Switch

Status

Represent a stat

u

w

ith s

w

itch toggled 

u

p.

Represent a stat

u

w

ith s

w

itch toggled 

do

w

n.

Switch position

Option

Functions

UNIT ID is 

“0x”

The [UNIT ID] rotary s

w

itch 

w

ill ha

v

e a setting range of 

01 thro

u

gh 0F.

UNIT ID is 

“1x”

The [UNIT ID] rotary s

w

itch 

w

ill ha

v

e a setting range of 

10 thro

u

gh 1F.

UNIT ID is 

“2x”

The [UNIT ID] rotary s

w

itch 

w

ill ha

v

e a setting range of 

20 thro

u

gh 2F.

UNIT ID is 

“3x”

The [UNIT ID] rotary s

w

itch 

w

ill ha

v

e a setting range of 

30 thro

u

gh 3F.

NOTE

Do not 

u

se a UNIT ID of “00” (DIP s

w

itches 1 and 2 

u

p

w

ard and the rotary s

w

itch at 0).

Switch position

Option

Function

NATIVE

Ena

b

les remote control 

w

ith 

the s

u

pported de

v

ices.

Summary of Contents for EXi8

Page 1: ... ZH RU IT ES FR DE EN 日本語 中文 Owner s Manual Bedienungsanleitung Mode d emploi Manual de instrucciones Manuale di istruzioni Руководство пользователя 取扱説明書 English Deutsch Français Español Italiano Русский ...

Page 2: ...o blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your out let consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience recepta cles and the point where they exit from the appara tus 11 Only use attachments accesso...

Page 3: ...lease contact the local retailer authorized to distrib ute this type of product If you can not locate the appropriate retailer please contact Yamaha Corporation of America Electronic Service Division 6600 Orangethorpe Ave Buena Park CA90620 The above statements apply ONLY to those products distrib uted by Yamaha Corporation of America or its subsidiaries This applies only to products distributed b...

Page 4: ...he device inspected by Yamaha service personnel The power cord or plug becomes frayed or damaged It emits unusual smells or smoke Some object has been dropped into the instrument There is a sudden loss of sound during use of the device If this device should be dropped or damaged immediately turn off the power switch disconnect the electric plug from the outlet and have the device inspected by qual...

Page 5: ...r damage to the internal components Do not place vinyl plastic or rubber objects on the device since this might discolor the panel When cleaning the device use a dry and soft cloth Do not use paint thinners solvents cleaning fluids or chemical impreg nated wiping cloths Condensation can occur in the device due to rapid drastic changes in ambient temperature when the device is moved from one locati...

Page 6: ...tallation flexibility with compact 1U chassis The EXi8 is an input expansion unit and the EXo8 is an output expansion unit The expansion unit can be installed to locations where only either input or output is required To make the EXi8 EXo8 parameter settings use the system s dedicated application software MTX Editor available for Win dows OS only The dedicated application software makes it easy to...

Page 7: ...NAL indicator that corresponds to the alert number will flash in green For explanations of the alerts refer to the Alert list on page 13 t POWER indicator This indicator will light when this device is powered on y NETWORK indicator This indicator will light green if a link is established with an external device via the rear panel NETWORK connector page 9 It will flash while data is being sent or r...

Page 8: ...fferent UNIT ID numbers in a range from 01 to 3F Switch 3 This switch is for future expansion Set this to its upward position Switches 4 5 REMOTE Settings of these switches are not necessary Set these to their upward position Rear Panel ON q w e r y u t i Illustration shows EXi8 NOTE The EXi8 EXo8 has some connectors that are shaped identically but have a completely different function e g NETWORK ...

Page 9: ...s and can also provide 48V phantom power The system s dedicated application software is used to specify the gain of the internal head amps and to turn the phantom power on off Use the included Euroblock plugs to make connections see Euroblock plug connection on page 10 for details i Cooling vent The EXi8 EXo8 contains a cooling fan The cooling air is exhausted here so please be careful not to bloc...

Page 10: ...s when making connections to the INPUT OUTPUT connectors 1 Loosen the terminal screws 2 Insert cables 3 Securely tighten the terminal screws Pull the cables not too strongly to confirm that they are securely connected 4 Use the included cable ties to fasten the cable to the tab Precautions for rackmounting Euroblock plug connection Cable preparation Use stranded wire for Euroblock connections and ...

Page 11: ...ORK indicator and the YDIF indicator will flash slowly Initialization failed The ALERT indicator will flash 4 When initialization is completed power off the EXi8 EXo8 once again 5 Set the rear panel DIP switches 7 and 8 to the RESUME position 6 Power on the EXi8 EXo8 again The EXi8 EXo8 will start up in its factory set state NOTE When connecting unbalanced cables to the INPUT con nector use a jump...

Page 12: ...ally assigned according to the UNIT ID No audio input is present INPUT SIGNAL indicator does not light Connect the cable properly Make sure that a signal from an external device is being input Set the gain of the internal head amplifier or external head amplifier to an appropriate level No audio is output OUTPUT SIGNAL indicator does not light Could the output level be lowered In the system s dedi...

Page 13: ...a problem with the connection of the YDIF IN connector Make sure that YDIF cables are properly connected Use cables that meet the required specifications 5 Duplicate IP addresses Change the IP addresses or UNIT ID so that there are no duplicates IP address was not set within 60 sec onds of startup Please check rear panel DIP switch 6 IP SETTING If DIP switch 6 is set to PC use the system s dedicat...

Page 14: ...ock plugs 3 pin tabbed x 8 cable ties x 8 Owner s manual Electrical specifications Sampling frequency 48kHz 44 1kHz Signal delay Less than 2 5ms Frequency response 20Hz to 20kHz 1 5dB min 0dB typ 0 5dB max Total harmonic distortion Less than 0 05 4dBu Gain 6dB less than 0 1 4dBu Gain 66dB Dynamic range 107dB Gain 6dB Equivalent input noise EIN 126dBu Gain 66dB Crosstalk Channel separation 100dB 1k...

Page 15: ...maha le plus pro che Las especificaciones y descripciones de este manual del propietario tienen sólo el propósito de servir como información Yamaha Corp se reserva el derecho a efectuar cambios o modificaciones en los productos o especificaciones en cualquier momento sin previo aviso Puesto que las especificaciones equipos u opciones pueden no ser las mismas en todos los mercados solicite informac...

Page 16: ...Appendix EXi8 EXo8 Owner s Manual 92 Dimensions 430 480 351 44 2 355 352 Unit mm ...

Page 17: ...vention de potentiels effets négatifs sur la santé humaine qui pourraient advenir lors d un traitement inappro prié des déchets Pour plus d informations à propos de la collecte et du recyclage des déchets d équipements électriques et électroniques veuillez contac ter votre municipalité votre service de traitement des déchets ou le point de vente où vous avez acheté les produits Pour les profession...

Page 18: ...EXi8 EXo8 Owner s Manual 94 ...

Page 19: ...ursal en España Ctra de la Coruna km 17 200 28230 Las Rozas Madrid Spain Tel 34 902 39 8888 GREECE Philippos Nakas S A The Music House 147 Skiathou Street 112 55 Athens Greece Tel 01 228 2160 SWEDEN FINLAND ICELAND Yamaha Music Europe GmbH Germany filial Scandinavia J A Wettergrens Gata 1 Box 30053 S 400 43 Göteborg Sweden Tel 031 89 34 00 DENMARK Yamaha Music Europe GmbH Tyskland filial Denmark G...

Page 20: ...Yamaha Pro Audio global web site http www yamahaproaudio com Yamaha Manual Library http www yamaha co jp manual ZG06180 C S G Pro Audio Division 2013 Yamaha Corporation 304POHD 01A0 Printed in China ...

Reviews: