EMX5016CF
110
Output Voltage (DC)
■
PS CIRCUIT BOARD REPAIR GUIDE
1.
Applicable Circuit Board
This guide is applicable when repairing the circuit board specified in the table 1-1.
Table 1-1
2.
Electrical Performance
2-1
Preparation
• Connect the INLET circuit board (WG970200 for U, A destination or WG970300 for H, B, O
destination) to CN402 and
CN410.
• Adjust the power supply voltage suites each circuit boards. Refer to the table 1-1 above.
• Connect the power cable to the AC inlet of the INLET circuit board.
2-2
Voltages of Each Part
The output voltage is normal if it is within the range specified in the table 2-1 when turning the power on.
Table 2-1
Note: The output voltage may be out of the range if it is measured without the load resistance or the power supply voltage
differs from the specified in the table 1-1.
2-3
Discharge
To prevent the electrical shock (discharge of the electric charge from the capacitor), discharge electricity between the follow-
ing part when handling the PS circuit board.
• Between the positive (+) and negative (-) terminals of C409 and C410. If you have left the unit for 10 minutes or more after
turning the power off, you do not have to discharge.
• Between CN405 and CN409.
• Between CN406 and CN408.
Circuit Board
PS
PS
PS
Part No.
WF534000
WF534100
WF534200
Destination
U
H, B, O
A
Power Supply
AC 120 V
AC 230 V
AC 240 V
H, B, O
U, A
+90.3
±
3 V
+46.7
±
3 V
-46.7
±
3 V
-90.3
±
3 V
+15.0
±
0.6 V
-15.0
±
0.6 V
+94.3
±
3 V
+48.6
±
3 V
-48.6
±
3 V
-94.3
±
3 V
+15.0
±
0.6 V
-15.0
±
0.6 V
5 k
Ω
, 3 W
5 k
Ω
, 3 W
5 k
Ω
, 3 W
5 k
Ω
, 3 W
10 k
Ω
, 1/4 W
10 k
Ω
, 1/4 W
+BH
+BL
-BL
-BH
+15 V
-15 V
CN405-CN407
CN406-CN407
CN408-CN407
CN409-CN407
CN902 1-2 pin
CN902 3-2 pin
Measuring Item
Measuring Part
Load Resistance