  3.  Remove four screws and remove the meter unit 

c

.

c

C

To avoid parts becoming damaged by static electricity, 
discharge the electricity from your body by touching the 
engine or other metal surface before servicing the meter 
unit.

  4.  Disconnect the engine switch coupler 

d

.

 

  

e

 ..... engine switch

  5.  Return the harness of receiver unit 

1

, and secure the 

harness using band 

2

.

  6.  Remove  grommet 

f

 temporarily, and pass the receiver 

unit harness through the grommet.

  7.  After passing the harness through the hole where the 

grommet 

f

 has been installed, install the receiver unit 

1

 

by screws 

3

. Install the grommet 

f

 in its original position.

c

C

Make sure that grommet 

f

 is secured to its original 

position.

  8.  Remove  cap 

g

 from the control panel, and attach switch 

label 

4

 to the panel.

NOTE:

Remove cap 

g

 by pressing its top and bottom hooks and by 

pulling the cap outward.

  9.  Install  remote  control  switch 

5

 by facing its terminal 

downward.

10.  Connect the coupler of wire harness 

6

 to the coupler of 

receiver unit (2 couplers), engine switch (2 couplers), and 
remote control switch (1 coupler).

c

d

e

f

f

1

1

2

f

1

3

UP

g

5

4

6

6

to receiver unit
(4P)

to receiver unit
(6P)

to remote control switch

to engine switch

to engine switch coupler 
(wire harness end)

white tape

7XF-2819W-10̲0409.indd   3

7XF-2819W-10̲0409.indd   3

2008/04/10   9:18:12

2008/04/10   9:18:12

Summary of Contents for EF4500iSE - Inverter Generator

Page 1: ...e this product in other countries as doing so may be illegal NOTE 8 The remote control can be used approximately 20 meters away from the generator if there are no obstacles between them 8 This communi...

Page 2: ...oving the control panel take care not to hang it by its wire leads It may damage the wire leads and cause damage to the generator After the screws have been removed from the control panel pass a wire...

Page 3: ...has been installed install the receiver unit 1 by screws 3 Install the grommet f in its original position cC Make sure that grommet f is secured to its original position 8 Remove cap g from the contr...

Page 4: ...again 12 Check the operation of remote control See How to use the remote control page 4 NOTE If the remote control does not operate normally check the connectors for poor or incorrect connection 13 R...

Page 5: ...equipment w Keep the remote control transmitter away from children and pets cC 8 Do not give the remote control transmitter any physical impact Take care not to drop 8 Do not place the heavy objects...

Page 6: ...e 0 5 second interval When this operation is correct indicator lamp 2 of the remote control transmitter lights for approximately 1 second And the startup signal is sent to the generator NOTE 8 To prev...

Page 7: ...FF Checking the voltage level of dry cell batteries When the generator is stopped hold down OFF button 1 of the remote control transmitter for longer than 0 5 seconds Indicator lamp 2 lights up twice...

Page 8: ...y the remote control transmitter need to transmit ID to the receiver after Installing procedure page 4 1 2 1 Remove the front panel and pull out the control panel See Installing procedure page 2 2 Dis...

Page 9: ...page 6 8 The dry cell batteries of remote control transmitter have discharged Replace the dry cell batteries See How to replace dry cell batteries page 7 8 The radio waves do not reach the generator...

Page 10: ...page 10 EF4500iSE remote control kit INSTALLATION AND OPERATION MANUAL 2008 by Yamaha Motor Corporation U S A Printed in Japan...