6F65G11
8-12
9
8
7
6
5
4
3
2
1
Ignition and ignition control system/Starting system
Starting system
Checking the fuse (WH,W)
1.
Check the fuse for continuity. Replace if
there is no continuity.
Checking the starter relay (WH, W)
1.
Connect the digital circuit tester leads to
the starter relay terminals.
2.
Connect the positive battery terminal to
the brown (Br) lead.
3.
Connect the negative battery terminal to
the black (B) lead.
4.
Check for continuity between the starter
relay terminals. Replace if there is no
continuity.
Checking the thermoswitch
1.
Place the thermoswitch in a container of
water and slowly heat the water.
2.
Check the switch for continuity at the
specified temperatures. Replace if out of
specification.
a
Temperature
b
Time
c
No continuity
d
Continuity
Checking the engine stop lanyard
switch (MH, WH)
1.
Check the engine stop lanyard switch for
continuity. Replace if there is no continu-
ity.
Thermoswitch continuity
temperature:
Pink (P) — Black (B)
e
: 84 — 90 °C (183 — 194°F)
f
: 60 — 74 °C (140 — 165°F)
6B480160
Switch position
Lead color
White (W) Black (B)
Clip removed
a
Clip installed
b
Engine shut-off
button pushed
c
Summary of Contents for E40G
Page 1: ...E40J SERVICE MANUAL 6F6 28197 5G 11 E40G ...
Page 4: ......
Page 16: ...GEN INFO 1 11 6F65G11 MEMO ...
Page 28: ...2 11 6F65G11 SPEC MEMO ...
Page 54: ...FUEL 4 13 6F65G11 MEMO ...
Page 101: ...6F65G11 6 4 9 8 7 6 5 4 3 2 1 Special service tools Backlash indicator 90890 06706 ...
Page 120: ...LOWR 6 23 6F65G11 Lower unit Shimming M T 6F660860 ...
Page 199: ......
Page 200: ...YAMAHA MOTOR CO LTD Printed in Japan Jul 2004 0 8 1 E Printed on recycled paper ...