background image

DX7_8X_EXP 

Page 6 of 6 

Install v2.22 

 

www.musictechnologiesgroup.com 

Preliminary 

Reassembly 

 
Remove all tools from the DX7. Carefully reassemble the DX7 in the reverse order, taking care to 
replace the correct screws in the various locations. If you disconnected the green keybed ground 
strap  wire don't forget to screw  it back in. Do not snag, tug  or otherwise interfere with the wires 
you have soldered on. 
 
 

Test 

 
Plug the AC cable in and turn it on. You should get a greeting message like:  
 

*  Welcome to  * 
*  DX7 8x Exp  * 

 

Troubleshooting: If you don't see this after a couple of seconds, you have probably soldered the 
wires onto the wrong spots or the solder connections are poor. All of the expansions have been 
tested in a real DX7 prior to shipping. Recommend removing whole expansion and start over. 

 
You can do a quick version check of the board by pressing and holding the front Function button 
and also pressing and holding buttons 16 and 32.  You should see something like the following: 
 

DX7 8x Exp v2.22 

Test Entry ? 

 
Press INTERNAL twice to return to the main screen (or press NO or power the DX7 off).  
 
 
 
Since  technically  the  battery  has  been  removed,  you  may  find 

some  of  the  standard  DX7 

Function  settings  have  been  scrambled

  (Eg.  Portamento  Time  usually).  Check/set  the 

standard DX7 Function settings versus your preferences.   
 
You will need to set the initial DX7_8X_EXP parameters on FUNCTION 13 (or 12) and then load 
up to 8 banks of 32 patches (what Yamaha calls Voices). Each bank must be activated by a patch 
selection (which will 

initially be garbled

 data) 

then

 the data can be loaded via cartridge or MIDI. 

 

Consult the online "Yamaha DX7 8x Expansion User Guide" for more information on using 
your upgraded DX7

 
For  your  convenience,  the  recommended  default  settings  for  FUNCTION  13  (or  12)  are  shown 
here: 

 

Midi Trns Ch= 1 

 

Vel OFFSET= 0 

 

2nd CH VOICE=1 

 

LOCAL ON 

 

SPLIT OFF 

 

ACTIVE SENSE=OFF 

 

 

Enjoy your updated DX7! 

See the MTG web site for more great vintage synth and drum machine goodies. 

Summary of Contents for DX7 8X EXP

Page 1: ...pening the DX7 ESD Precautions and Proper Handling Procedures You should observe standard static safe handling behavior when working with sensitive electronic equipment such as synthesizers o Avoid carpets in cool dry areas o Dissipate static electricity before handling any system components by touching a grounded metal object o If possible use anti static devices such as wrist straps and floor ma...

Page 2: ...your patches if they are important to you Open the DX7 Using a Philips head screwdriver remove the 5 screws from the front panel Two are located on the left front Two are located on the right front A final one is located on the right rear Set the screws aside noting that the rear panel one is the shortest Re Move the Keybed Remove the Keyboard Rail Some of the solder connections are very close to ...

Page 3: ...Or if you prefer disconnect the cables and completely remove the keybed This will give you access to the 3 screws holding the silver keyboard rail in place Remove those three screws and set aside the silver keyboard rail Shown here with keybed removed You now have excellent access to the DX7 main board If you do remove the keybed you may find it easier to remove the small yellow cable and large fl...

Page 4: ...T install the circuit board at this time Carefully unplug the 3 conductor cable from the DX7_8X_EXP board and set the board aside The 3 wires that make up this cable need to be soldered onto chips that are already present on the DX7 main board Do not mistake the wire colors for power and ground They are not The cable is about twice the length you need for the standard installation Some alternate s...

Page 5: ...e 28 pins that form a DIP package align with the vacated IC14 spot The 7 pins along the edge should align with IC21 Do not press the board in place yet You can use a small mirror to check the pin alignment Once you are happy that all the pins are aligning with the desired locations firmly and evenly press the DX7_8X_EXP board in place Make a visual check to see that the board is flush with the soc...

Page 6: ...ton and also pressing and holding buttons 16 and 32 You should see something like the following DX7 8x Exp v2 22 Test Entry Press INTERNAL twice to return to the main screen or press NO or power the DX7 off Since technically the battery has been removed you may find some of the standard DX7 Function settings have been scrambled Eg Portamento Time usually Check set the standard DX7 Function setting...