7
KP125
INSPECTION OF FUNCTION
(機能検査)
1. Inspection
Environment
1-1 Surrounding
Temperature,
Humidity
Base temperature is 30 ±10 degrees C, and humidity
is not speci
fi
ed. However, prevent inspections when
condensation occurs.
1-2 Devices
Used
●
Drum trigger module DTXPRESS
Ⅳ
etc.
●
Storage oscilloscope
●
Connecting cords
●
The power ampli
fi
er and speakers for monitors
●
Drum stick
●
Mallet with felt beater (for tenor drum, etc.)
●
Electric drum pad TP65 (for an inspection jig)
●
In addition, the jig needed for inspection
1-3 Connection
of
Devices
It connects, as shown in a
fi
gure.
*
It takes care that a product does not get atta-
ching a scratch to a product.
q
Connect the output of KP125 to the [
i
KICK/9]
jack of DTXPRESS
Ⅳ
and the oscilloscope in
pallarel using stereo cables.
w
Connect the output of DTXPRESS
Ⅳ
to the
ampli
fi
re and the speakers.
OUTPUT
TP65
(
jig
(
治具
))
OUTPUT
INPUT
KP125
Stereo cable
S
S
R
R
T
T
Stereo cable
SP
*1
*2
TRIG. INPUT
*
KICK/9
OUTPUT
L/MONO
INPUT
DTXPRESS
Ⅳ
Oscilloscope
ch1
ch2
Mallet (Beater part)
(マレット(ビーター部))
TIP
RING
SLEEVE
* 1
C o n n e c t t o t h e [ K I C K ] j a c k
when using a trigger module
other than the DTXPRESS
Ⅳ
.
* 1 DTXPRESS
Ⅳ
以外のトリガー
モジュールを使 用する場合には
[KICK]端子へ接続してください。
* 2
Waveform from the TP6 5
can be checked through ch2.
* 2 ch2 は TP65 からの波形が確
認できます。
1.
検査環境
1-1
周囲温度、湿度
温度は 30 ± 10℃を基準とし、湿度は特に規定し
ません。ただし、結露した状態での検査は避けて
ください。
1-2
使用機器
●
ドラムトリガーモジュール DTXPRESS Ⅳなど
●
ストレージオシロスコープ(2ch 以上): 1 台
●
接続コード類 : 一式
●
モニター用パワーアンプ、スピーカ : 一式
●
ドラムスティック : 1 本
●
フェルトビーター付きマレット(テナードラム用
等): 1 本
●
電子ドラムパッド TP65(検査治具として): 1 台
●
他、検査に必要な治具類 一式
1-3
機器の接続
図のように接続します。
※ 製品の保持、打撃で傷がつかないよう注意して
ください。
q
KP125 の出力を、
ステレオケーブルで DTXPRESS Ⅳ
の [
i
KICK/9] 端子およびオシロスコープに並
列に接続します。
w
DTXPRESS Ⅳの出力を、アンプ、スピーカに接
続します。