1-3. Preparation
• The load resistors for each output terminals are as
follows.
SP OUT(CN300)
: 4
Ω
(Rated 500W or more)
SP OUT(CN500)
: 8
Ω
(Rated 100W or more)
• 0dBu is referenced to 0.775Vrms. 0dBV is referenced
to 1Vrms.
• Unless otherwise speci
fi
ed, the controls should be set
as follows.
Level control
: 10 (MAX)
MIC/LINE switch
: LINE
HPF switch
: OFF
D-CONTOUR switch
: OFF
FRONT LED DISABLE switch
: OFF
• Unless otherwise speci
fi
ed, the input signal should be 1
kHz sine wave.
• The output impedance of signal generator should be
150
Ω
.
1-4. Activating diagnostic mode and application
for service inspection
The inspection must be performed with both the diagnostic
mode of the unit and the application for service inspection
of PC are activated.
Follow the steps below.
(1) With the FRONT LED DISABLE switch turned off,
turn on the power to the amp assembly. After about 4
seconds, the diagnostic mode is activated and all LEDs
on the rear panel blink at intervals of 500ms.
(2) Run application for service inspection (DiagDSR-
SERVICE.exe).
2. Inspection
Items
2-1. Power
consumption
Ground the input terminal via 150
Ω
resistor.
Con
fi
rm that the power consumption is 40 W or less.
1-3. 準備
・ 各出力端子に下記の負荷抵抗を接続します。
SP OUT(CN300) :4 Ω(定格 500W 以上)
SP OUT(CN500) :8 Ω(定格 100W 以上)
・ 0 dBu = 0.775 Vrms、0 dBV = 1 Vrms とします。
・ 特に指定のない場合、コントロールツマミ類は以
下のように設定します。
LEVEL コントロール
:10(最大)
MIC/LINE スイッチ
:LINE
HPF スイッチ
:OFF
D-CONTOUR スイッチ
:OFF
FRONT LED DISABLE スイッチ
:OFF
・ 特に指定のない場合、入力信号は 1 kHz 正弦波と
します。
・ 信号発生器の出力インピーダンスは 150 Ωとしま
す。
1-4. ダイアグモードとサービス検査用アプリケー
ションの起動
検査は、本体のダイアグモードと PC のサービス検査
用アプリケーション両方を起動した状態で行います。
以下の操作をします。
(1) FRONT LED DISABLE スイッチをオフにした状
態でアンプ Ass'y の電源を入れます。
約 4 秒後、ダイアグモードが起動し、リアパネ
ルにある全 LED が 500 ms 間隔で点滅します。
(2) サービス検査用アプリケーション(DiagDSR-
SERVICE.exe)を起動します。
2.
検査項目
2-1. 消費電力
入力端子を 150 Ωの抵抗を介して接地します。
消費電力が 40 W 以下であることを確認します。
DSR112/DSR115/DSR215/DSR118W
52