background image

 

3

 

■ 

 

Precautions

 

• Do not place a container with liquid or small metal 

objects on top of this unit. Liquid or metal objects 
inside this unit are a fire and electrical shock hazard.

• Do not allow water to enter this unit or allow the unit 

to become wet. Fire or electrical shock may result.

• Connect this unit’s power cord only to an AC outlet of 

the type stated in this Owner’s Manual or as marked 
on the unit. Failure to do so is a fire and electrical 
shock hazard.

• Do not scratch, bend, twist, pull, or heat the power 

cord. A damaged power cord is a fire and electrical 
shock hazard.

• Do not place heavy objects, including this unit, on top 

of the power cord. A damaged power cord is a fire and 
electrical shock hazard. In particular, be careful not to 
place heavy objects on a power cord covered by a car-
pet.

• Be sure to ground the unit to avoid the risk of electri-

cal shock

• If you notice any abnormality, such as smoke, odor, or 

noise, or if a foreign object or liquid gets inside the 
unit, turn it off immediately. Remove the power cord 
from the AC outlet. Consult your dealer for repair. 
Using the unit in this condition is a fire and electrical 
shock hazard.

• Should this unit/AC adapter/power supply be 

dropped or the cabinet be damaged, turn the power 
switch off, remove the power plug from the AC outlet, 
and contact your dealer. If you continue using the unit 
without heeding this instruction, fire or electrical 
shock may result.

• If the power cord is damaged (i.e., cut or a bare wire is 

exposed), ask your dealer for a replacement. Using the 
unit with a damaged power cord is a fire and electrical 
shock hazard.

• Do not remove the unit’s cover. You could receive an 

electrical shock. If you think internal inspection, 
maintenance, or repair is necessary, contact your 
dealer.

• Do not modify the unit. Doing so is a fire and electri-

cal shock hazard.

• When rack-mounting the unit, allow enough free 

space around the unit for normal ventilation. This 
should be: 10 cm behind, and 20 cm above.

• For normal ventilation during use, remove the rear of 

the rack or open a ventilation hole.

• If the airflow is not adequate, the unit will heat up 

inside and may cause a fire.

• This unit has ventilation holes at the rear and bottom 

to prevent the internal temperature rising too high. 
Do not block them. Blocked ventilation holes are a fire 
hazard. 

• Hold the power cord plug when disconnecting it from 

an AC outlet. Never pull the cord. A damaged power 
cord is a potential fire and electrical shock hazard. 

• Do not touch the power plug with wet hands. Doing 

so is a potential electrical shock hazard.

• The digital circuits of this unit may induce a slight 

noise into nearby radios and TVs. If noise occurs, 
relocate the affected equipment.

• If the message “WARNING LOW BATTERY!” appears 

when you turn on this unit, contact your dealer as 
soon as possible about replacing the internal data 
backup battery. The unit will still operate correctly, 
but data other than the presets will be lost. 

• Before you replace the battery, store your data to an 

ATA-compliant PC flash storage card via the CS1D, or 
store the data to the personal computer by connecting 
the computer to the PC CONTROL “RS-232-C” con-
nector on the DSP1D/DSP1D-EX.

• The unit is equipped with the ground connector to 

avoid the risk of electrical shock.

• Be sure to ground the unit before you insert the power 

plug into an AC outlet.

• If the power cord has three pins and the ground con-

nector on the AC outlet is grounded, the unit will be 
grounded effectively.

 

Operating Notes

 

• The power must be turned on/off using the POWER 

switch of this unit. Do not turn the power on/off by 
plugging in the power cable, or by using a power strip 
or circuit breaker. Doing so may cause malfunctions.

• Do not rapidly turn on and off the POWER switch of 

this unit. Doing so may cause excessive current to 
damage the system. You must allow at least five sec-
onds to elapse between power-on and power-off.

• For this unit, be sure to use a power voltage of the 

value specified in the Specifications section of this 
Owner’s Manual. If you apply a higher or lower volt-
age, a malfunction may result.

 

Rack Mounting Caution

 

If the unit is rack mounted and transported regularly, 
for example, when on a tour, we recommend that the 
rear of the unit be supported by fitting a pair metal 
brackets, one each side. The following drawing pro-
vides the information necessary to make such brackets.
Note that only one bracket is shown here and the 
bracket for the other side must be bent in the opposite 
direction.

86.5

20.5

3.1

4-

ø

6.5

2-R2

R2

2-R2

R5

t = 1.6

(82.1)
76.2

44.45

31.75

5.9

0

36.5

14.5

7.5

8

0

12

134

200

0

Summary of Contents for DSP1D

Page 1: ...V480360 R2 1 IP 16 200 CR Printed in Japan Owner s Manual EX E ...

Page 2: ...ion 6600 Orangethorpe Ave Buena Park CA 90620 The above statements apply ONLY to those products distributed by Yamaha Corporation of America or its subsidiaries WARNING THIS APPARATUS MUST BE EARTHED IMPORTANT THE WIRES IN THIS MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE GREEN AND YELLOW EARTH BLUE NEUTRAL BROWN LIVE As the colours of the wires in the mains lead of this apparatus...

Page 3: ...om to prevent the internal temperature rising too high Do not block them Blocked ventilation holes are a fire hazard Hold the power cord plug when disconnecting it from an AC outlet Never pull the cord A damaged power cord is a potential fire and electrical shock hazard Do not touch the power plug with wet hands Doing so is a potential electrical shock hazard The digital circuits of this unit may ...

Page 4: ...up the unit Never perform installation and setup by yourself POWER ON OFF A B ENGINE ID 1 2 CONTROL I O 48CH 96CH INPUT CONFIGURATION POWER ON OFF A B ENGINE ID 1 2 CONTROL I O 48CH 96CH INPUT CONFIGURATION 1 2 3 4 2 2 2 2 IN OUT IN 2 OUT IN 1 1 IN 5 3 1 9 7 5 3 1 2 OUT 6 4 2 10 8 6 4 2 OUT THRU PC CONTROL WORD CLOCK TIME CODE IN GPI RS 422 REMOTE IN OUT OFF ON RS 232 C USB 75Ω MIDI OUTPUT INPUT C...

Page 5: ... Windows 95 or Windows 98 to control the PM1D system from the PC Use a D sub 9 pin cross cable female to female to connect the RS 232 C port to the serial COM port on the PC The USB port is provided for future system expansion but it is not operative in the current software version G WORD CLOCK IN jack 75 Ω ON OFF switch and WORD CLOCK OUT jack The WORD CLOCK IN jack is used to provide word clock ...

Page 6: ...it to avoid the risk of electrical shock before you insert the power plug into an AC outlet This product comes with a 3 pin power cord If the ground connector of the AC outlet has already been grounded the unit will be grounded effectively by using the 3 pin power cord Grounding the unit is also effective for preventing hum and other noise Specifications Digital I Os Sampling frequency External sy...

Page 7: ... specified in EN55103 1 and EN55103 2 Inrush Current 31A Conformed Environment E1 E2 E3 and E4 Unit Input channel DPS1D INPUT 1 48 ST IN 1 4 The DSP1D has an empty slot available for the IDB1D board DPS1D EX INPUT 1 96 ST IN 1 8 DSP1D IDB1D for expansion POWER ON OFF A B ENGINE ID 1 2 CONTROL I O 48CH 96CH INPUT CONFIGURATION 460 8 450 480 399 2 408 7 9 5 unit mm ...

Page 8: ...YAMAHA CORPORATION Pro Audio Digital Musical Instrument Division P O Box 3 Hamamatsu 430 8651 Japan ...

Page 9: ...取扱説明書 EX J ...

Page 10: ...のないよう 十 分にご注意ください この機器の上に水などの入った容器や小さな 金属物を置かないでください こぼれたり 中に入ったりすると 火災 感電の原因にな ります ご使用になるとき 電源コードを傷つけたり 加工したり 無理 に曲げたり ねじったり 引っ張ったり 加 熱したりしないでください コードが破損し て 火災 感電の原因になります この機器の裏ぶたやカバーは絶対に外さない でください 感電の原因になります 内部の点検 整備 修理が必要と思われると きは 販売店にご依頼ください この機器を改造しないでください 火災 感 電の原因となります 雷が鳴りだしたら 早めに機器本体の電源ス イッチを切り 電源プラグをコンセントから 抜いてください 落雷のおそれがあるとき 電源プラグが接続 されたままならば 電源プラグには触れない でください 感電の原因となります 使用中に異常が発生したとき ...

Page 11: ...ずかな雑音が 近 くのラジオやテレビに入る可能性があります そのような ときは 両者を少し離してください アース線を接続する この機器は重いので 持ち運びは必ず2人以上 でおこなってください オーディオラックなどに入れるときは 放熱 をよくするために 壁や他の機器との間に隙 間をとってください 隙間の大きさは 背面 では10cm 天面では20cm以上必要です さらにラックの背面を開放するか もしくは ラックの背面に相当の通風孔を開けてくださ い 放熱が不十分だと内部に熱がこもり 火災の 原因となることがあります 本機には感電防止のため 専用のアース端子 が設けられています 電源プラグをコンセントに挿入する前に確実 に大地アースを施してください 3芯電源コードの場合にはコンセント側のアー ス端子が大地と接地されていれば上記と同じ 効果があります 電源の投入について 電源のオン オフは 必ず本...

Page 12: ... 2 CONTROL I O 48CH 96CH INPUT CONFIGURATION POWER ON OFF A B ENGINE ID 1 2 CONTROL I O 48CH 96CH INPUT CONFIGURATION 1 2 3 4 リアパネル 2 2 2 2 IN OUT IN 2 OUT IN 1 1 IN 5 3 1 9 7 5 3 1 2 OUT 6 4 2 10 8 6 4 2 OUT THRU PC CONTROL WORD CLOCK TIME CODE IN GPI RS 422 REMOTE IN OUT OFF ON RS 232 C USB 75Ω MIDI OUTPUT INPUT CONTROL I O CONSOLE CONSOLE I O CASCADE DIGITAL I O 1 IN 5 3 1 9 7 5 3 1 2 OUT 6 4 2...

Page 13: ...NPUT CONFIGURATION 48CHのイ ンジケーター が点滅 ワー ドクロ ックがロ ッ ク していない 4 POWER ON OFF スイ ッチ DSP1D DSP1D EXの電源スイ ッチです 電源オンのと き のイ ンジケーターが点灯します 5 MIDI IN OUT THRU 端子 外部MIDI機器との間でプログラムチェンジなどの MIDIメ ッセージを送受信するための端子です 6 PC CONTROL RS 232 C USB 端子 Windows95 Windows98が動作するPC パーソナル コ ンピューター を接続し PCからPM1Dシステムをコ ン ト ロールするための端子です RS 232 C端子は D sub 9ピンクロスケーブル メス メス を使ってPCのシ リ アル COM 端子と接続してく ださい USB端子は現在 のソフ ト ウェアバージ ョ ン...

Page 14: ...フピッチ68ピンコネクター メス 2 DIGITAL I O CONSOLE I O 1 2 RS 422 D subハーフピッチ68ピンコネクター メス 2 CONTROL I O CONSOLE 1 IN OUT 0 225V 1 825V 50 Ω BNCコネクター 2 CONTROL I O CONSOLE 2 IN OUT 0 225V 1 825V 50 Ω BNCコネクター 2 REMOTE RS 422 RS 422 D sub 9ピンコネクター メス GPI C MOS IN Open collector OUT D sub 25ピンコネクター メス 1ピン 150 mA 8ピン ト ータル 500 mA TIME CODE IN SMPTEフォーマッ ト 定格 10 dB 10 kΩ XLR 3 31タイ プコネクター MIDI IN OUT THRU MIDIフォーマ...

Page 15: ...UT 1 48 ST IN 1 4 DSP1D EX INPUT 1 96 ST IN 1 8 DSP1D 増設IDB1D DSP1DはIDB1Dボー ド用空スロ ッ ト有り 寸法図 POWER ON OFF A B ENGINE ID 1 2 CONTROL I O 48CH 96CH INPUT CONFIGURATION 460 8 450 480 399 2 408 7 9 5 単位 mm 仕様および外観は改良のため予告なく 変更する ことがあ り ます 高調波ガイ ドライ ン適合品 ...

Page 16: ...高松市丸亀町8 7 株 ヤマハミュージック神戸 高松店内 広 島サービスステーション 082 874 3787 731 0113 広島市安佐南区西原6 14 14 九 州サービスステーション 092 472 2134 812 8508 福岡市博多区博多駅前2 11 4 本 社 CSセンター 053 465 1158 435 0016 浜松市和田町200 ヤマハ 株 和田工場6号館2階 所在地 電話番号などは変更されることがあります 2001年8月現在 保証書 この商品には保証書がついています 販売店でお渡し してい ますから ご住所 お名前 お買上げ年月日 販売店名など所定 事項の記入および記載内容をおた しかめのうえ 大切に保管し てく ださい 保証書は当社がお客様に保証期間内の無償サービスをお約 束するもので この商品の保証期間はお買上げ日より1年です 保証期間内の転居や ご贈答用に購...