No.9 AD DATA CHECK
The A/D conversion values of the microcomputer which detects key scan port, protection detection port, etc. are displayed
in % (100%:5V).
The keys on the main unit cannot be operated to detect the values of all keys in the K1/K2 and SI.
Turning the rotary encoder (input selector on the main unit) will switch the sub-menu.
K1/K2: Panel key on the main unit.
Initial display.
(See Table 1.)
SI: Tuner signal sensitivity level
DC: DC protection value
(normal value: 1-13)
PS: Power voltage protection value
Table 1
(normal value: 23-38)
AD Value
0
15
25
35
45
55
65
75
85
SET MENU
PROGRAM
INPUT MODE
NEXT
TAPE/MD MON
/EXT DECODER
EFFECT
K1
K2
–
+
9. AD DA T A CHK
9. K 1 : 1 0 0 K 2 : 1 0 0
9. S I :
0
9. DC :
7
9. P S :
3 0
Cautions:
1. If K1 and K2 are more than
±
4% from the reference values, normal operation will not be executed.
2. If DC and PS are outside the nor mal values, the protection function will operate and power will turn off.
Ignore this display item as this unit is not equipped with a tuner.