Dynamic Range
fs=48kHz or 96kHz
<DME8i-C/DME8o-C>
<DME4io-C>
Crosstalk@1kHz
reference to the level of output N
<DME8i-C/DME8o-C>
<DME4io-C>
LED Level Meter
<DME8i-C>
<DME8o-C>
Input
Output
RL
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT 1–4
OUTPUT 1–4
600
Ω
Rs=150
Ω
, GAIN: –60dB
All input & output level controls: 0dB
–128
EIN
EIN
–127
dBu
–64
dBu
Rs=150
Ω
, GAIN: +10dB
All input & output level controls: 0dB
–82
–79
dBu
* Hum & Noise are measured with a 6dB/octave filter @12.7kHz; equivalent to a 20kHz filter with infinite dB/octave
attenuation.
Input
Output
RL
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT 1–8
OUTPUT 1–8
600
Ω
GAIN: +10dB
106
dB
Input
Output
RL
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT 1–4
OUTPUT 1–4
600
Ω
GAIN: +10dB
106
dB
* Dynamic range are measured with a 6dB/octave filter @12.7kHz; equivalent to a 20kHz filter with infinite dB/octave
attenuation.
from
to
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT N
OUTPUT (N–1) or (N+1)
N = 1–8, GAIN: +10dB
–80
dB
from
to
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT N
OUTPUT (N–1) or (N+1)
N = 1–4, GAIN: +10dB
–80
dB
* Crosstalk is measured with a 18dB/octave filter @80kHz
METERING POINT
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT 1–8
PEAK red LED: ON
–3
dBFs
SIGNAL green LED: ON
–40
dBFs
METERING POINT
CONDITIONS
MIN
TYP
MAX
UNITS
OUTPUT 1–8
PEAK red LED: ON
–3
dBFs
SIGNAL green LED: ON
–40
dBFs