Internal Design of the CP5 & CP50
Left & Right Parts
[RIGHT2] (CP5)
[LEFT]/[RIGHT] (CP50)
Song Setting Area
TRACK Part
MIC INPUT Part
Settings for All Parts
Settings for All Performances
45
CP5/CP50 Reference Manual
4
CtrlAsn
(Controller Assign)
This parameter is used to select the controller to be assigned.
Setting values:
For the CP5
FC1 (Foot Controller 1), FC2 (Foot Controller 2), or FS (assignable foot switch)
For the CP50
FC (Foot Controller) or FS (assignable foot switch)
FC1 or FC2
(CP5) / FC
(CP50)
Foot controller connected to the corresponding FOOT CONTROLLER
jack
FS
Foot switch connected to the ASSIGNABLE jack
CtrlNo
(Control Number)
This parameter is used to specify a control change number for the controller
selected using
CtrlAsn
.
Setting values:
If
CtrlAsn
is set to “FC1”, “FC2”, or “FC”
00 (off), or 01 to 95
If
CtrlAsn
is set to “FS”
00 (off), 01 to 95, 98 (Ply/Stop), 99 (PcInc), or 100 (PcDec)
5
RcvCh
(Receive Channel)
This parameter is used to set the channel on which to receive MIDI messages.
Setting values:
1 to 16, omni, or off
omni
Messages will be received on all MIDI channels.
TxCh
(Transmit Channel)
This parameter is used to set the channel on which to transmit MIDI messages pro-
duced by playing the keyboard and operating controllers.
Setting values:
1 to 16, or off
NOTE
If the
ZoneSw
parameter from the Common Settings area’s Zone Edit screen is set
to “on”, the
TxCh
parameter will have no effect and MIDI messages will be
transmitted in line with that screen’s
TransCh
settings (page 32).
LocalSw (Local
Control Switch)
This parameter is used to turn local control on and off. When “off” is selected, the
stage piano's built-in Tone Generator is essentially disconnected from the keyboard
and controllers, and no sound will be produced in response to playing of the key-
board. The stage piano does, however, continue to transmit MIDI messages when
LocalSw
has been set to “off”, and the Tone Generator will continue to produce
sound in response to MIDI messages received from external devices.
Setting values:
on or off
6
DevNo.
(Device Number)
This parameter is used to set a MIDI device number for your CP5 or CP50. In order to
successfully exchange Bulk Dump data, parameter changes, or other system exclu-
sive messages, this number must match the Device Number of the external MIDI
device.
Setting values:
1 to 16, all, or off
all
System exclusive messages for all MIDI device numbers will be
received. Meanwhile, data will be transmitted from the stage piano using
Device Number 1.
off
No exchange of Bulk Dump data, parameter settings, or other system
exclusive messages with other devices will be possible. In addition, an
error message may be displayed if you attempt to perform such an oper-
ation.
In/Out
(MIDI In/Out)
This parameter is used to specify the interface to be used for exchanging MIDI mes-
sages.
Setting values:
MIDI or USB
MIDI
The MIDI connectors will be used.
USB
The USB TO HOST port will be used.
NOTE
It is not possible to exchange MIDI messages via the MIDI connectors and the
USB TO HOST port at the same time. Be sure, therefore, to set this parameter
correctly in accordance with your equipment setup.
Page
On-screen name
(and full name)
Description