CLP-150/CLP-150M/CLP-150C
7
4.
Circuit Boards & Assemblies Inside of
Main Unit
(Time required : About 10 minutes each)
4-1
Remove the top board assembly. (See procedure 2)
4-2
Each circuit board and assembly can be removed by
removing its fixing screws as listed below.
5.
PEDAL (DJK) Circuit Board
(Time required : About 10 minutes)
5-1
Remove the top board assembly. (See procedure 2)
5-2
Disconnect the PK-LF cable. (Fig. 3)
5-3
Remove the PK connector assembly. (See procedure 4)
5-4
Remove the two (2) screws marked [26c]. The pedal
connector angle can then be removed from the PEDAL
(DJK) circuit board. (Fig. 5)
(Fig. 5)
(Fig. 4)
Circuit board and Assembly Ref. No.
Screw
QTY Fig.
DM Shield Cover Assembly
56A
Bind Head Tapping Screw-B 3.0x6 MFZN2Y (EP600130)
6
4
(U.S.A. model only)
DM Assembly
56B
Bind Head Tapping Screw-B 3.0x6 MFZN2Y (EP600130)
12
4
Network Circuit Board
58
Bind Head Tapping Screw-1 3.5x20 MFZN2Y (EP030470)
4
4
PK Connector Assembly
81A
Bind Head Tapping Screw-1 3.5x12 MFZN2Y (EP030240)
2
4
MA Cover Assembly
81B
Bind Head Tapping Screw-1 3.5x12 MFZN2Y (EP030240)
2
4
(U.S.A. model only)
MA120 Assembly
81C
Bind Head Tapping Screw-1 3.5x12 MFZN2Y (EP030240)
2
4
Jack Assembly
81D
Bind Head Tapping Screw-1 3.5x12 MFZN2Y (EP030240)
4
4
FU Cover Assembly
81E
Bind Head Tapping Screw-1 3.5x12 MFZN2Y (EP030240)
2
4
(U.S.A. model only)
FU120LB Assembly
81F
Bind Head Tapping Screw-1 3.5x12 MFZN2Y (EP030240)
2
4
Power Transformer
80A
Bind Head Tapping Screw-B 4.0x10 MFZN2BL (EP600240)
4
4
PEDAL
[26c]
[26c]
(DJK)
Pedal connector angle
Power transformer
MA120 assembly
[56A] x 6
[56B] x 12
[58] x 4
[81A] x 2
[81B] x 2
[81C] x 2
[81D] x 4
[81E] x 2
[81F] x 2
[80A] x 4
NET1
MA cover assembly
DM shield cover
assembly
PK connector assembly
FU cover assembly
FU120LB assembly
Jack assembly
[26c]: Bind Head Tapping Screw-B 3.0x8 MFZN2BL (EP600190)
DM assembly